83
Setting Up Parameters
Jog.MinusActivate
When this destination is activated, jogging motion will begin in the negative direction. The jog velocity is determined by
which jog (Jog0 or Jog1) is active or not. A jog stops when this destination is deactivated. If the jog velocity is negative,
Jog.MinusActivate will cause the motor to jog in the positive direction.
Jog.Select0
This destination is used to select between Jog0 and Jog1. When the Jog.Select0 destination is not active, the target velocity
for the jog is the Jog.0.Velocity. If the Jog.Select0 destination is active, the target velocity of the jog is the Jog.1.Velocity.
Jog.Select0 can be toggled “On” or “Off” while jogging. Jog acceleration and deceleration ramps are used to ramp between
jog velocities.
Below is a description of jog operation using these destinations.
Note
In the table below Jog.0.Velocity = 100 RPM and Jog.1.Velocity = -500 RPM.
All Jog destinations are level sensitive.
Figure 77: Jog Activation
Figure 78: Jog Select Details
If the Jog direction is reversed, the Jog.#.Decel value will be used to decelerate the motor to zero speed and then the
Jog.#.Accel will be used to accelerate to the new (opposite sign) velocity.
Jog.PlusActivate Jog.MinusActivate Jog.Select0 Motion
Off Off Off 0 RPM
On Off Off +100 RPM
Off On Off -100 RPM
On Off On -500 RPM
Off On On +500 RPM
On On Off 0 RPM
On On On 0 RPM