Emerson Epsilon EP Drive 400518-01 Manual de instalación Pagina 77

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 240
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 76
65
Setting Up Parameters
Figure 60: Queue Object and Components Diagram
A detailed explanation of each of the queue components is as follows:
Queue Data
The queue data is loaded into the queue by statements in the user program. Two types of data are most often used with the
queue: Position Feedback, and Master Position Feedback.
Queue Size
This is the maximum number of elements that can be stored in the queue. If more pieces of data than this number are in the
queue at a time, then a Queue Overflow source will activate.
Queue Offset
The Queue Offset is the value that is added to the Queue Data and then compared to the selected source to determine when
the Queue Exit event activates. For instance, if the source in selected source is set to Feedback Position, and the Queue Offset
is set to 10, and the user puts the value 5 into the queue, the Queue Exit source will activate when the Feedback Position is
greater than or equal to 5 + 10 or 15.
Full Level
The amount of data in the queue is constantly monitored and the Queue Full source will activate when the number of pieces
of data in the queue exceeds the Full Level parameter. This is only a flag and does not indicate a fault of any kind.
Source
The Source determines which parameter the sum of the Queue Data and Queue Offset are compared to in order to activate
the Queue Exit function. If set to FeedBackPosn (Position Feedback), the sum of the data and offset are compared to the
Position Feedback parameter. If set to MasterPosn (Master Position), then the sum is compared to the Master Feedback
Position parameter, and if set to CommandPosn (Command Position), then the sum is compared to the Motor Commanded
Position.
Name
You can assign a descriptive name to each queue, making the setup easier to follow. The length of the text string is limited
by the column width with a maximum of 12 characters. Simply double click on the Name field of any queue’s line to assign
a name to it.
Number of Queue Units
This selects the number of Queues available. Maximum of eight.
Queue Sources and Destinations
Sources
Queue Exit - This source activates when the Comparitor Select parameter is greater to or equal to the sum of the data entered
into the queue, and the queue offset.
Queue Empty - This source is active if no data is stored in the queue. It will become inactive when the first piece of data is
loaded into the queue and remain inactive until all data has been removed from the queue.
Data[ ]
Size
Offset
Full Level
Comparitor Select
Name
Queue Object
Clear
Compare
Enable
Exit
Empty
Full
Overflow
Data In
Q
ueue Data = X
Data Out
Y =
Q
ueue Data
Vista de pagina 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 239 240

Comentarios a estos manuales

Sin comentarios