56
Epsilon EP-P Drive and FM-3/4 Module Reference Manual
When online, the Active Faults window, Reset button and Power Up group window become active. There will also be three tabs that
appear, Fault Log, Fault Counts, and Drive Fault Log.
Figure 51: Faults View Online - Faults Log Tab
Active Faults Group
The Active Faults group contains the Active Faults window.
Active Faults Window
This window displays any active faults in the system. Those faults which do not require a reboot can be cleared by clicking
on the Reset button. For more detailed fault information, refer to “Diagnostics and Troubleshooting” on page 189.
Power Up Group
These parameters will be active when online with the drive.
Drive Power Up Count
This parameter shows the number of times the drive has been powered up since the last reset by the factory.
Drive Power Up Time
This parameter shows the time, in hours, since the drive was last powered up.
Drive Total Power Up
This parameter shows the total time that the drive has been powered up since reset by the factory.
Module Power Up Count (FM-3/4 only)
This parameter shows the number of times the function module has been powered up since the last reset by the factory.
Fault Log Tab
The Fault Log tab is visible when online and consists of a list of the ten most recent faults detected by the drive or module.
These are saved in non-volatile memory to be preserved during power down.
Faults are listed in reverse order of occurrence-the most recent fault is listed first, and older faults are pushed off the list.