Emerson Epsilon EP Drive 400518-01 Manual de instalación Pagina 210

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 240
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 209
198
Epsilon EP-P Drive and FM-3/4 Module Reference Manual
drag and drop the parameter from the Drag Source window on the left over to the Parameters Displayed in Watch Window
on the right and it will be added to the Watch Window.
Figure 123: The Watch Window
Once a parameter is added to the Watch Window, it’s current value or state is constantly monitored. If a parameter in the
window changes value or state, it will change to a red color. It will remain red until it hasn’t changed for a period of 4 seconds.
After 4 seconds, the parameter will turn back to black in color. This allows the user to see what has changed recently without
looking directly at every parameter.
The following are descriptions of the buttons and controls on the Select Parameters window:
Clear All
By clicking on the Clear All button, all of the parameters in the Parameter Displayed in Watch Window pane will be erased
and the Watch Window closes.
Save Selections
By clicking on Save Selections, the user can save the specific parameters that have been added to the Watch Window. Once
the selections have been saved, the Restore Selections button can be used to monitor all the same parameters the next time
the user opens the Watch Window. Therefore, if there is a list of helpful diagnostic parameters the user wishes to see when
online, those specific parameters can be saved and recalled in the Watch Window at any time. The settings are saved in a file
named “fm3watch.wch”.
Restore Selections
By clicking on the Restore Selections button, the Watch Window will be filled with the list of parameters that were last saved
using the Save Selections button.
Select Defaults
The Select Defaults button adds the most commonly used parameters to the Watch Window.
Select I/O
The Select I/O button will add the module/base drive or drive digital inputs and outputs to the Watch Window.
Close
The Close button will close the Select Parameters window, while the Watch Window will remain open.
Help
The help button will give associated help on the Watch Window setup.
User Level
The User Level setting is a filter for the parameters that are seen in the Select Drive Parameters list. If set to Easy, the
parameters used in most basic applications will be seen while the more advanced parameters are hidden. If set to Detailed,
the parameters used in more advanced applications will be added to the list. If set to Too Much, then all parameters available