166
Epsilon EP-P Drive and FM-3/4 Module Reference Manual
Figure 103: Making Assignments
The Input Lines view shows the assignments that have been made to the Inputs group of Sources on the Assignments view.
Notice that a Name can be associated to each input line. Each input line can also have a debounce time.
Name – This 12-character string allows a descriptive name assigned to an input line. This makes the configuration easier to
follow.
Debounce – This is the minimum time a specific input must be on, for recognition by the drive/FM-4 module. This helps
prevent false triggering for applications in electrically noisy environments. The units for this parameter are seconds, with
resolution of 0.001 seconds.
The Output Lines view shows assignments that have been made to the Outputs group of Destinations on the Assignment view.
Assignments to this view are made in the same way as assignments to the Input Lines view. After all assignments have been
made, the Output Lines view may look like Figure 104.
Figure 104: Output Lines View
A name can also be given to each hardware output line. Figure 104 shows how to enter a name for an individual output line.
Name – This 12-character string allows a descriptive name assignment to an output line. This makes the configuration easier
to follow.
Drag and
Drop Method
Comentarios a estos manuales