134
Epsilon EP-P Drive and FM-3/4 Module Reference Manual
7 = Module program fault
8 = No Program
9 = DN Connection Time Out
10 = DN Bus Off
11 = DN Duplicate Mac ID
12 = Module Trajectory
13 = PB Parameterization fault
14 = PB Watchdog fault
15 = PB Configuration
All other bits are not used. A "1" in these bit locations indicates the specific fault is active, and a "0" is inactive.
Reset Faults
Fault.Reset
Resets faults that do not require a power down. This event is "or"ed with the reset button on the drive.
Fault Log - Fault Type
FaultLog.#.FaultType
This is the fault identifier for the current fault log entry. It is a read only parameter for the logged fault.
It may hold a value for any fault supported by the device. They are the same as the faults listed on the Assignments View for
Faults.
Code FM-3/4
00 EncoderStates
01 EncoderHardware
03 PowerModule
04 LowDCBus
05 HighDCBus
08 IsrOverrun
09 TrajectoryFault
0A Synchronization
10 WatchdogTimer
13 OverSpeed
14 InvalidConfiguration
15 PowerUpSelfTest
18 RMSShuntPower
19 MotorOverTemperature
1A OverTemperature
1E Auto-Tune
20 WatchdogTimer
21 InvalidConfiguration
22 NVMInvalid
23 PowerUpTest
24 FollowingError
25 TraveLimitPlus
26 TraveLimitMinus
27 ProgramFault
28 NoProgram
29 DevicenetConnTimeout
2A DevicenetBusOffInt