58
Epsilon EP-P Drive and FM-3/4 Module Reference Manual
Fault Code
This is the faults parameter name.
Fault Counts
This is the number of times that the fault has occurred.
Clear Module Counts button
Pressing this control button will zero the Fault Counts of all module faults.
Drive Fault Log Tab (FM-3/4 only)
Figure 53: Faults View - Drive Fault Log Tab
The Drive Fault Log tab is visible when online and consists of a list of the ten most recent faults detected by the drive. These
are saved in the drive’s non-volatile memory to be preserved during power cycles. Faults are listed in reverse order of
occurrence so that the most recent is listed first.
Fault Code
The fault code has the same description of the fault that is or was reported in the Active Faults window.
Power Up (Counts)
This is the Drive Power Up Counts when the fault was detected.
Time (Hours.Minutes)
This is the Drive Power Up Time when the fault was detected.
PLS View
The PLS View allows users to define Programmable Limit Switches (PLS) for advanced machine operation. By selecting
PLS in the Hierarchy Tree, the PLS View will appear on the right (see Figure 54).