Setting Up Parameters
places for both values is taken from the selected module variable. MaxOutputValue is the maximum analog output value
which corresponds to the maximum user value.
Minimum Value
The analog output is a linear interpolation of the selected module variable between the minimum and maximum specified end
points. Each end point is specified as the user value and the corresponding output value at that point. The number of decimal
places for both values is taken from the selected module variable. MinUserValue is the minimum user unit value which
corresponds to the minimum analog output value.
Minimum Output
The analog output is a linear interpolation of the selected module variable between the minimum and maximum specified end
points. Each end point is specified as the user value and the corresponding output value at that point. The number of decimal
places for both values is taken from the selected module variable. MinOutputValue is the minimum analog output value which
corresponds to the minimum user value.
Feedback
Analog Output Feedback is the Analog output voltage to be sent out after scaling the selected source parameter.
Motion Group
All motion parameters related to Jogs, Homes, Indexes and Gearing are located in the Motion hierarchy group.
Motion views will use units that correspond to Realtime or Synchronized motion. This choice is made on each motion view.
The units are customized in the Setup Group: Realtime units are defined on the User Units View, and Synchronized units are
defined on both the User Units View and the Master Units View.
Each of the motion views, when online, have an Online tab that displays feedback information and provides buttons to initiate
motion.
Jog View
Jogging produces rotation of the motor at controlled velocities in a positive or negative direction. The jog is initiated with the
Jog.#.Initiate destination or from a program.
Figure 76: Jog View
Jog Number
This box allows you to select between Jog0 and Jog1 setup views.