157
Parameter Descriptions
(hardware or software) are no longer valid. If disabled using a program, the travel limits will automatically be re-enabled
when the program ends, if they haven’t already been enabled. This feature is typically used when a machine must use one of
its limit switches as a home switch. The user disables the travel limits, then homes to the limit switch, and then re-enables the
travel limit.
Torque Limit
TorqueLimitEnable
This destination is used to enable the TorqueLimit. This is level sensitive.
Travel Limit Minus Activate
TravelLimitMinusActivate
This destination is used to activate the travel limit minus fault. It should be assigned to the travel limit minus sensor. When
it is activated the drive will decelerate to a stop using the deceleration rate defined in the TravelLimitDecel parameter. This
is level sensitive.
Travel Limit Minus Active
TravelLimitMinusActive
This source is active when the TravelLimitMinusActivate is active.
Travel Limit Plus Activate
TravelLimitPlusActivate
This destination is used to activate the travel limit plus fault. It should be assigned to the travel limit plus sensor. When it is
activated the drive will decelerate to a stop using the deceleration rate defined in the TravelLimitDecel parameter. This is
level sensitive.
Travel Limit Plus Active
TravelLimitPlusActive
This source is active when the TravelLimitPlusActivate is active.
Decimal Places
TorqueUnits.Decimal
This parameter is the decimal point location for user torque units.
Units Name
TorqueUnits.Name
The User can specify a torque unit name of up to 12 characters. Default is % Cont.
Percent Continuous
TorqueUnits.PercentContinuousCurrent
This parameter is the denominator of torque scaling factor. This is an amount of continuous current in percent that is equal
to the TorqueUnits.Torque parameter.
Torque
TorqueUnits.Torque
This parameter is the numerator of the torque scaling factor. This is an amount of torque in Torque User Units that is
equivalent to one unit of PercentContinuousCurrent (denominator of scaling factor). This scaling factor is used to relate actual
current or torque to user units.