191
Diagnostics and Troubleshooting
Fault Descriptions
Flash Invalid
This fault indicates that the firmware checksum has failed. Use the Tools Program Flash menu item from PowerTools to
reprogram/upgrade the firmware stored in flash memory. If this problem persists, call Control Techniques. A common cause
would be an interrupted F/W Flash upgrade (cable disconnected during an upgrade process).
Encoder State Cycle Power Yes Enc St
Encoder Hardware Cycle Power Yes Enc HW
Motor Overtemp Reset Button or Input Line Yes Mtr Tmp
RMS Shunt Power Reset Button or Input Line Yes Shnt Pw
Overspeed Reset Button or Input Line Yes Overspd
Max Following Error Reset Button or Input Line Yes Flw Err
Travel Limit +/- Auto No
Trav (-)
Trav (+)
All "On"
Normally on for one
second during power up
Yes
FM-3 Reset Button or Input Line Yes
** Fault **
<Fault Description>
FM-4 Reset Button or Input Line Yes
** Fault **
<Fault Description>
DeviceNet or Profibus
(FM-4DN and FM-4PB only)
Reset Button
Dependent on
Fault
**Fault**
<Fault Description>
Drive Overtemp
(MDS only)
Allow drive to cool down,
Cycle Logic Power
Yes DvOvrTmp
Segment Display Fault Action to Reset Bridge Disabled
FM-3/4 Keypad Display
(When Applicable)
Vista de pagina 202