155
Parameter Descriptions
Shunt Active
ShuntActive
This source is active when the drive's internal shunt is active (conducting current).
Shunt Power RMS
ShuntPowerRMS
This parameter models the thermal heating and cooling of the drive internal shunt. This parameter indicates the percent of
shunt capacity utilization and is based on the Heat Sink RMS value. When this value reaches 100 percent the drive will
generate an RMS Shunt Power Fault. This is only applicable to the EN-208 and EN-214.
Enable Software Travel Limits
SoftwareTravelLimitEnable
Software travel limits can be used to limit machine travel. They are often setup inside the hardware travel limits to add a level
of protection from exceeding the machines travel limits. The SoftwareTravelLimitMinusActive source (output function) is
active when the SoftwareTravelLimitMinusPosn is reached or exceeded. Motion is halted using the TravelLimitDecel
whenever a hardware or software travel limit is hit or exceeded. Software travel limits are not active unless Absolute Position
Valid is active.
Software Travel Limit Minus Activate
SoftwareTravelLimitMinusActive
The SoftwareTravelLimitMinusActive source is active when the SoftwareTravelLimitMinusPosn is reached or exceeded.
Motion will come to a stop using the TravelLimitDecel ramp. Software travel limits are not active unless enabled and
Absolute Position Valid is active.
Software Travel Limit Plus Activate
SoftwareTravelLimitMinusPosn
The SoftwareTravelLimitMinusActive source will activate when the SoftwareTravelLimitMinusPosn is reached or exceeded.
Motion will come to a stop using the TravelLimitDecel. Software travel limits are not active unless enabled and Absolute
Position Valid is active.
Software Travel Limit Plus Active
SoftwareTravelLimitPlusActive
The SoftwareTravelLimitPlusActive source is active when the SoftwareTravelLimitPlusPosn is reached or exceeded. Motion
will come to a stop using the TravelLimitDecel ramp. Software travel limits are not active unless enabled and Absolute
Position Valid is active.
Software Travel Limit Plus Position
SoftwareTravelLimitPlusPosn
The SoftwareTravelLimitPlusActive source is active when the SoftwareTravelLimitPlusPosn is reached or exceeded. Motion
is halted using the TravelLimitDecel whenever a hardware or software travel limit is hit or exceeded. Software travel limits
are not active unless enabled and Absolute Position Valid is active.
Start Up
StartUp
This source can be used to trigger an event to occur on startup (when the FM-4 module powers up or is rebooted). This source
is typically used to initiate a program or to initiate a home so that a machine will automatically home on power up or reboot.
StartUp will activate when the FM-4 module has powered up and no faults are active. Startup may take as long as five seconds
to activate. Depending on what the Startup source is assigned to, the drive may need to be enabled to perform the function.
If the drive is not enabled, the startup source cannot initiate programs or motion. The source will remain active until the FM-
4 module is powered down.