18
Epsilon EP-P Drive and FM-3/4 Module Reference Manual
.
Figure 28: Upload Drive Configuration Dialog Box
Select the device to upload and click Upload.
Downloading
Downloading is the process of sending the configuration created with PowerTools Pro from the PC to the device. Changes
made in PowerTools Pro will not take effect until the information has been downloaded or the Update to RAM button has
been clicked.
To download information to a device, click the Download button on the PowerTools Pro toolbar or from the Device
menu, choose Download. The Download to Device IDx dialog box will open, all communication connections are
scanned and the results appear. In Figure 29, one device on COM port 1 was found, it’s a EN-204 with FM-3/4DN
module. The Upload Drive Configuration dialog box contains the following information for every device found:
Ip Address/COM
Modbus Address ID
Drive Type
Module Type
Communication Options
Base/Drive FW Revision
Module FW Revision
Module Serial Number
Drive Serial Number