128
Epsilon EP-P Drive and FM-3/4 Module Reference Manual
Bit Number Value
Bit.B#
This read/write bit may be used in a program as an intermediary variable bit controlled by the user. Bit.B# is one of 32 bits
that make up the BitRegister parameter. Assigned to communication networks such as DeviceNet, Profibus and Modbus,
Bit.B# may be used to transfer events that have occurred in a PLC to the FM-3/4 program.
Note
When the value of Bit.B# is changed, the value of BitRegister.#.Value is changed as well.
Bit Register Number Value
BitRegister.#.Value
This parameter is made up of the combination of the 32 Bit.B#. The BitRegister.#.Value. The BitRegister.#.Value register
may be accessed bitwise by using Bit.B#, or double word-wise by using BitRegister.#.Value.
Bit Register Number Value Mask
BitRegister.#.ValueMask
This parameter is the Mask for the BitRegister.#.Value. Each bit location is set to either transfer the current data in the
corresponding bit location of BitRegister.#.Value (by setting the bit location to 1) or to clear the current data in
BitRegister.#.Value (by setting the bit location to 0).
Brake Activate
Brake.Activate
This destination, when activated, engages the brake. This is simply used to manually engage the brake outside of the normal
brake operation. This is level sensitive.
Brake Disengaged
Brake.Disengaged
This source is used to control the motor holding brake. When it is "off" the brake is mechanically engaged. When the brake
is engaged, the diagnostic display on the front of the drive will display a "b". The drive and module outputs are limited to 150
mA capacity, therefore, a suppressed relay is required to control the brake coil. Model BRM-1 may be used.
Brake Release
Brake.Release
This destination will release the brake under all conditions, even when Brake.Activate is engaged. When this input function
is active, the Brake.Disengaged output function (source) will be activated. This is used as a manual brake override.This is
level sensitive.
Capture Enable
CaptureEnable
The CaptureEnable is used to enable or “arm” the capture component. If the CaptureEnable is not active, then the
CaptureActivate has no effect, and the CaptureTriggered remains inactive. Once the CaptureEnable is activated, the Capture
component is ready and waiting for a CaptureActivate signal to capture data. CaptureEnable is a read-only destination on the
Assignments view, and is accessible through a user program.
Capture Activate
CaptureActivate
If the Capture component is enabled and has been reset (CaptureTriggered is inactive), then the rising edge of
CaptureActivate will capture the four data parameters and cause CaptureTriggered to be activated. If the Capture component
is not enabled, or has not been reset, the CaptureActivate will be ignored.