156
Epsilon EP-P Drive and FM-3/4 Module Reference Manual
Stop
Stop
Activate this destination to stop all motion and programs. If Stop is activated when a Jog, Index, Home or Program is in
progress, they will decelerate to zero speed at the Stop Decel ramp. When Stop is active, all Jog, Home, Index and Program
initiate destinations will be ignored. When it is deactivated, all level sensitive and active input functions (Jog.0.PlusActivate,
Jog.0.MinusActivate, etc.) will become operational. For example, if the Jog.PlusActivate input function is active when the
Stop input function is deactivated, the Jog.Plus motion will initiate using the acceleration found in the Jog.0.Accel parameter.
This is level sensitive.
Stop Deceleration
StopDecel
Deceleration rate used when the Stop destination is activated.
Torque Command
TorqueCommand
This parameter is the torque command value before it is limited. The torque command may be limited by either the Torque
Limit (if the Torque Limit Enable destination is active) or current foldback.
Limited Torque Command
TorqueCommandLimited
This is the actual torque commanded to the motor. This value is the result after the TorqueCommand is limited by the current
foldback or the TorqueLimit value (if enabled).
Torque Level
TorqueLevel
This parameter is compared to the TorqueCommand. If the absolute value of the TorqueCommand is greater than or equal to
the TorqueLevel the TorqueLevelActive source is activated. This parameter is specified in Torque User Units.
Torque Level Active
TorqueLevelActive
This source is used to indicate that the absolute value of the TorqueCommand is greater than or equal to the TorqueLevel
setting.
Torque Limit
TorqueLimit
This is the level to which the TorqueCommand will be limited when the TorqueLimitEnable input function is active.
Torque Limit Active
TorqueLimitActive
Active when the TorqueCommand is greater than the TorqueLimit and the TorqueLimitEnable input function is active.
Travel Limit Deceleration
TravelLimitDecel
This parameter defines the ramp used to decelerate the motor to a stop when any travel limit is activated.
Travel Limit Disable
TravelLimitDisable
TravelLimitDisable can be used from the Assignments view, or through a user program. It can be used to temporarily disable
the travel limit fault capability of the FM-4 module. When TravelLimitDisable is activated, the FM-4 module travel limits