Emerson Epsilon EP Drive 400518-01 Manual de instalación Pagina 88

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 240
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 87
76
Epsilon EP-P Drive and FM-3/4 Module Reference Manual
Total Binary Value = 3
Therefore, Selector.Selection3 would activate.
The Selector.Select lines can change without any action until the Selector.SelectorInitiate destination is activated.
Selector.Selection sources can be tied to any destination in the Assignments view. Figure 70 shows the four selection lines
being tied to Index 0 through Index 3 initiates. By doing this, we could initiate up to four indexes with only two select lines
and a selector initiate. This can help minimize the number of inputs required to initiate a large number of indexes or programs.
Input Lines View
The Input Lines View displays any functions that have been assigned to the drive or module hardware inputs. See Figure 71.
Note
No assignments can be made using the Input Lines View, assignments are only displayed in the Input Lines View.
Figure 71: Input Lines View for an FM-3/4 Module
The following two functions can be performed on the Input Lines view.
Name
You can assign a descriptive name to each input and make the setup easier to follow. The length of the text string is limited
to a maximum of 12 characters. Simply double click on the Name field of any input line to assign a name to it.
Debounce
You can program a “Debounce Time” to any input line, which means the motion profile will need to be steady for at least the
debounce time before it is recognized. This feature helps prevent false triggering in applications in noisy electrical
environments. At the end of the debounce time, the next action can occur.
Figure 72: Input Line Diagram