Rosemount Analytical Inc. A Division of Emerson Process Management Setup and Operation 3-1
World Class 3000
SECTION 3
SETUP AND OPERATION
See Safety Data Sheet 1M03296 for safety related information.
3-1 OVERVIEW
Ensure that the oxygen analyzer, heater power
supply, and intelligent field transmitter have
been properly connected. It is important to
check that grounding and screening of termina-
tions are correctly made to prevent the introduc-
tion of ground loops. The IFT is equipped with
noise suppression circuitry on the power supply
and signal input lines. Proper grounding at in-
stallation will ensure accuracy of function.
The following five languages can be selected
within the IFT:
English Italian
French Spanish
German
The Intelligent Field Transmitter may be sup-
plied with any one of three configurations.
These configurations are the blind version, dis-
play only version, and the deluxe version. The
three versions differ as follows.
a. Blind Version
HART connections must be made out-
side of the hazardous area. Because
the Hart option is not protected by en-
ergy limiting barriers, it must not be
interfaced from within a hazardous
area. The signal cables should be
routed outside the hazardous area and
the connections made external to the
hazardous area.
The blind version has no display and no
keypad. With this version, an external HART
communications device is required. Refer to
Appendix JX regarding the HART Commu-
nications option.
b. Display Only Version (LDP)
The display only version is also known as
the LED Display Panel (LDP) version. This
IFT contains a bright LED display and a
four-key pad. The LDP version provides for
calibration capability only.
c. Deluxe Version (GUI)
The deluxe version is also known as the
General User Interface (GUI) version. This
IFT contains an LED display, liquid crystal
display panel, and an eight-key pad that al-
lows probe and electronics configuration,
calibration, and troubleshooting of the probe
and electronics.
This section of the manual deals with operator
controls and displays available with the GUI
equipped IFT. Operating parameters are listed
and instructions are included for viewing and
changing them.
Operating instructions for the IFT equipped with
the LDP and four membrane keys are included
in Section 4.
Any procedures not associated with normal op-
eration are included in Section 2, Installation, or
Section 5, Troubleshooting.