INTRODUCTION:
FLAMEPROOF APPARATUS OR NON FLAMEPROOF APPARATUS:
POWER DOWN PROCEDURE:
ISOLATION OF ELECTRICAL SUPPLY:
RESTORATION OF SUPPLY FOR ELECTRICAL TESTING:
REMOVAL OF JUNCTION BOX COVER:
WIRING OF THF APPARATUS:
INSTRUCTION BULLETINS (USER MANUAL):
CABLE GLANDS:
THIS SAFETY DATA SHEET APPLIES TO BOTH, HEATER POWER SUPPLY
3000 (HPS3000), TYPE No. 1U05667 AND TO DIGITAL ELECTRONICS, TYPE No. 1U03083.
THESE APPARATUS ARE CERTIFIED EExd IIC T6.
ISSeP CERTIFICATE No. 92C.103.1037, AND INIEX CERTIFICATE No. 87.103.578.
THESE APPARATUS HAVE BEEN DESIGNED AND MANUFACTURED TO OPERATE
SAFELY IN CERTAIN TYPES OF POTENTIALLY EXPLOSIVE ATMOSPHERES. IT IS ESSENTIAL
THAT THE EQUIPMENT IS NOT TAMPERED WITH OR DAMAGED IN ANY WAY WHICH
MIGHT LEAD TO A REDUCTION IN IT'S ABILITY TO OPERATE SAFELY IN SUCH POTENTIALLY
EXPLOSIVE ATMOSPHERES. FOR YOUR OWN SAFETY AND THE SAFETY OF OTHERS
PLEASE BRING ANY DAMAGE TO THE ATTENTION OF THE RESPONSIBLE AUTHORITY.
THESE APPARATUS HAVE BEEN DESIGNED AND MANUFACTURED IN ACCORDANCE
WITH EUROPEAN STANDARDS EN50014 & EN50018. INSTALLATION MAINTENANCE
AND REPAIR MUST BE IN ACCORDANCE WITH THE OFFICIAL “CODES OF
PRACTICE ON THE INSTALLATION AND MAINTENANCE OF ELECTRICAL APPARATUS
IN POTENTIALLY EXPLOSIVE ATMOSPHERES” FOR THE COUNTRY OF INSTALLATION
(EXAMPLE: BS5345 IN GREAT BRITAIN). ONLY APPROPRIATELY TRAINED PERSONNEL
ARE AUTHORIZED TO PERFORM ANY WORK ON THIS EQUIPMENT. SUCH PERSONNEL IN
ADDITION TO OPERATING TO THE ABOVE MENTIONED SAFETY STANDARDS, SHOULD TAKE
NOTE OF THE FOLLOWING SAFETY ISSUES.
(1)
THE ROSEMOUNT ENCODE SHEETS (PRODUCT ORDERING MATRIX) ALLOWS A CUSTOMER
TO ORDER EITHER THE HAZARDOUS AREA (FLAMEPROOF) VERSION OF THE APPARATUS
OR THE NON HAZARDOUS AREA VERSION. THE HAZARDOUS AREA VERSION HAS THE
SYMBOL “EExd” ON THE APPARATUS NAMEPLATE. THE NON HAZARDOUS AREA VERSION
DOES NOT. ENSURE THAT IF YOU HAVE RECEIVED THE NON HAZARDOUS AREA VERSION
THAT YOU DO NOT INSTALL IT IN A POTENTIALLY EXPLOSIVE ENVIRONMENT.
(2)
THIS PIECE OF APPARATUS IS NOT ITSELF FITTED
WITH A MEANS OF ELECTRICAL ISOLATION. CONSULT YOUR LOCAL CODES OF PRACTICE
ON THE INSTALLATION AND MAINTENANCE OF ELECTRICAL APPARATUS IN POTENTIALLY
EXPLOSIVE ATMOSPHERES (BS5345 IN BRITAIN) FOR INSTRUCTION ON THE ISOLATION OF
ELECTRICAL SUPPLY TO THE APPARATUS. FURTHER MORE THERE MUST BE “EFFECTIVE
MEASURES TO PREVENT THE RESTORATION OF SUPPLY TO THE APPARATUS WHILE THE
RISK OF EXPOSING UNPROTECTED LIVE CONDUCTORS TO AN EXPLOSIVE ATMOSPHERE
CONTINUES”:BS5345 PART 1 1989 SECTION 18.
“WHERE, FOR PURPOSES OF
ELECTRICAL TESTING, IT IS ESSENTIAL TO RESTORE THE SUPPLY BEFORE THE APPARATUS
IS REASSEMBLED, THEN THIS WORK SHOULD BE UNDER A CONTROLLED PROCEDURE
AND THE SPECIFIC LOCATION ASSESSED TO ENSURE THAT POTENTIALLY FLAMMABLE
GAS OR VAPOUR IS ABSENT”:BS5345 PART 1 1989 SECTION 23.
DO NOT REMOVE THE JUNCTION BOX COVER
WHILE THE APPARATUS IS ENERGIZED. WAIT 10 MINUTES AFTER DEENERGIZING BEFORE
OPENING THE APPARATUS.
(3) EACH APPARATUS MUST BE WIRED AS DETAILED IN
THE APPLICABLE INSTRUCTION BULLETIN (USER MANUAL).
(4) THE APPLICABLE INSTRUCTION BULLETINS ARE:
IB-106-300NEX:“EXCHANGE PROBE” CONFIGURATION & “FULLY CENELEC” CONFIGURATION.
IB-106-300NFX: USED WITH IFT3000 ELECTRONICS.
IB-106-300NCX: USED WITH CRE3000 ELECTRONICS.
THESE INSTRUCTION BULLETINS CONTAIN ESSENTIAL INFORMATION & MUST BE USED
WHEN WORKING ON THE APPARATUS.
(5) HAWKE CABLE GLAND, TYPE ICG653 (BASEEFA CERTIFICATE:
BAS No. EX 85B1258U) OR AN EQUIVALENT MUST BE USED. THIS GLAND IS A
BARRIER (STOPPER) GLAND. A FEATURE OF THIS GLAND IS THAT A COMPOUND
FILLED PACKING MATERIAL (PUTTY), FORMS A BARRIER BETWEEN THE INDIVIDUAL
INSULATED CONDUCTORS OF THE CABLE. THIS BARRIER ACTS TO PREVENT ENTRY
INTO THE CABLE OF THE PRODUCTS OF AN EXPLOSION WITHIN THE ENCLOSURE.
THIS GLAND IS CERTIFIED EExd IIC.
THIS DRAWING AFFECTS CENELEC CERTIFICATION.
NO REVISION ALLOWED WITHOUT CHECKING AND
APPROVAL BY THE PRODUCT ENGINEER.
DEO
DEO
DEO
05554
17-2-93
05856
05933
13-12-93
7-4-94
1
2
3
T
IT
L
E
SIZE
SCALE
DWG NO
SHEET
SAFETY DATA SHEET FOR
CENELEC APPROVED HPS3000 &
CENELEC APPROVED DIG. ELECTRONICS
1OF2
1M03243