Instruction Manual
106-300NFX Rev. 4.2
January 2002
2-12 Installation Rosemount Analytical Inc. A Division of Emerson Process Management
World Class 3000
LG. BR
GN/YE
BL
SHIELD
SHIELD
SHIELD
CAL RET
NO GAS
LO GAS
HI GAS
IN GAS
SHIELD
SHIELD
STACK TC -
STACK TC +
PROBEMV+
PROBE MV -
PROBE TC +
PROBE TC -
GN
RD
WH
SM.BR
WH
SM. BR
GN
RD
INTELLIGENT FIELD
TRANSMITTER IFT3000
WC 3000 PROBE
(CENELEC APPROVED)
12345678
WH
SM. BR
RD
GN
PROBE INTERIOR
GN/YE
BL
LG. BR
GN CELL -VE
OR CELL +VE
YE CHROMEL
RD ALUMEL
GN
BK
BK
}
HEATER
PROBE JUNCTION
BOX WIRING
STACK TC WIRING AS REQUIRED
SPECIAL PROBE CABLE BETWEEN PROBE AND
IFT BY ROSEMOUNT (FITTED WITH EExd
GLANDS)
INSTALL JM1 ON INTERCONNECT BOARD
INSTALL JM6 ON MICROPROCESSOR BOARD
IF STACK TEMPERATURE NOT USED
IF MPS 3000 NOT USED
1 RELAY PER PROBE AVAILABLE FOR
CALIBRATION STATUS INDICATION
(48 V max, 100 mA max)
CABLE COLORS SHOWN HERE APPLY TO
ROSEMOUNT SUPPLIED SPECIAL CABLE FITTED
WITH EExd GLANDS
(P/N 1U03066)
NOTES
ALWAYS DISCONNECT LINE VOLTAGE
FROM INTELLIGENT FIELD TRANSMITTER
BEFORE CHANGING JUMPERS.
LINE
VOLTAGE
SECTION
JUMPER
(INSTALL)
PROBE HEATER
VOLTAGE SECTION
JUMPER
(INSTALL)
120 V.A.C.
220 V.A.C.
240 V.A.C.
J1
J5 J6
J1
JM1
JM5JM6
J2
J3
J4
J5
J6
J7
J8
J9
3D39122G REV
POWER SUPPLY BOARD
3D3911BG REV
MICROPROCESSOR BOARD
3D39120G REV
INTERCONNECT BOARD
JM8, JM7, JM1
JM6, JM5, JM2
JM6, JM5, JM1
WORLD CLASS PROBE
218 PROBE
JM10
JM9
JUMPER CONFIGURATION
CAL RET
CAL RET
CAL RET
CAL RET
HI GAS
HI GAS
HI GAS
HI GAS
IN CAL
IN CAL
IN CAL
IN CAL
NO GAS
NO GAS
NO GAS
NO GAS
LO GAS
LO GAS
LO GAS
LO GAS
NC NC NCNC C C CCNONONONO
J13 J14 J15 J16 J17 J18
J12
J9
LINE IN
LL
NN
J8J7J6J5J4J3J2J1
LINE OUT
J10
J11
PROBE 1
PROBE 1
PROBE 2
PROBE 2
PROBE 3
PROBE 3
PROBE 4
PROBE 4
J19 J20 J21 J22
3D39064G REV
5 CONDUCTOR SHIELDED CABLE
PER PROBE #16 AWG BY CUSTOMER
L
E
E
N
N
L
LINE
VOLTAGE
LINE
VOLTAGE
MPS TERMINATION BOARD
MPS3000 MULTI GAS SEQUENCER (OPTIONAL)
ER
H
35870007
Figure 2-7. Wiring Layout for IFT 3000 (CENELEC approved) System without HPS