Instruction Manual
106-300NFX Rev. 4.2
January 2002
Rosemount Analytical Inc. A Division of Emerson Process Management Installation 2-1
World Class 3000
SECTION 2
INSTALLATION
2-1 OXYGEN ANALYZER (PROBE)
INSTALLATION
Before probe installations, consult
probe Safety Data Sheet 1M03226.
The probe and probe abrasive shield
are heavy. Use proper lifting and
carrying procedures to avoid
personnel injury.
Install all protective equipment covers
and safety ground leads after installa-
tion. Failure to install covers and
ground leads could result in serious
injury or death.
a. Selecting Location
1. The location of the probe in the stack
or flue is most important for maximum
accuracy in the oxygen analyzing pro-
cess. The probe must be positioned so
that the gas it measures is representa-
tive of the process. Best results are
normally obtained if the probe is posi-
tioned near the center of the duct (40
to 60% insertion). A point too near the
edge or wall of the duct may not pro-
vide a representative sample because
of the possibility of gas stratification. In
addition, the sensing point should be
selected so that the process gas tem-
perature falls within a range of 10° to
704°C (50° to 1300°F). Figure 2-1
provides you with mechanical installa-
tion references.
2. Check the flue or stack for holes and
air leakage. The presence of this
condition will substantially affect the
accuracy of the oxygen reading.
Therefore, either make necessary
repairs or install the probe upstream
of any leakage.
3. Ensure that the area is clear of
obstructions internal and external that
will interfere with installation. Allow
adequate clearance for removal of
probe (Figure 2-1).
Do not allow the temperature of the
probe junction box to exceed 150°C
(302°F) or damage to the unit may
result. If the probe junction box tem-
perature exceeds 150°C (302°F), the
user must fabricate a heat shield or
provide adequate cooling air to the
probe junction box.
b. Mechanical Installation
1. Ensure that all components are avail-
able for installation of the probe. Check
the ceramic filter to ensure that it is not
damaged and that the system cable is
the required length.
2. The probe may be installed intact as it
is received. It is recommended that you
disassemble the adapter plate for each
installation.
3. Weld or bolt adapter plate (Figure 2-1)
onto the duct.