Reference Manual
00809-0200-4801, Rev CA
July 2010
B-35
Rosemount 3051S
Expanded
1C PlantWeb housing Aluminum G
1
/2
1L PlantWeb housing SST G
1
/2
2C Junction Box housing Aluminum G
1
/2
2G Junction Box Housing with output for remote display and interface Aluminum G
1
/2
Wireless Options (Requires option code X and wireless PlantWeb housing)
Update Rate
Standard Standard
WA User Configurable Update Rate
Operating Frequency and Protocol
Standard Standard
3 2.4 GHz DSSS, WirelessHART
Omnidirectional Wireless Antenna
Standard Standard
WK Long Range, Integral Antenna
WM Extended Range, Integral Antenna
SmartPower
Standard Standard
1
(13)
Power Module Adapter, Intrinsically Safe (Power Module separate)
Other Options (Include with selected model number)
PlantWeb Control Functionality
Standard Standard
A01
(14)
FOUNDATION
fieldbus Advanced Control Function Block Suite
PlantWeb Diagnostic Functionality
Standard Standard
D01
(14)
FOUNDATION
fieldbus Diagnostics Suite
DA2
(14)(15)
Advanced HART
®
Diagnostics Suite
PlantWeb Enhanced Measurement Functionality
Standard Standard
H01
(14)(16)
FOUNDATION
fieldbus Fully Compensated Mass Flow Block
Mounting Bracket
(17)
Standard Standard
B4 Coplanar flange bracket, all SST, 2-in. pipe and panel
B1 Traditional flange bracket, CS, 2-in. pipe
B2 Traditional flange bracket, CS, panel
B3 Traditional flange flat bracket, CS, 2-in. pipe
B7 Traditional flange bracket, B1 with SST bolts
B8 Traditional flange bracket, B2 with SST bolts
B9 Traditional flange bracket, B3 with SST bolts
BA Traditional flange bracket, B1, all SST
BC Traditional flange bracket, B3, all SST
Software Configuration
Standard Standard
C1
(18)
Custom software configuration (Requires Configuration Data Sheet)
C2 Custom flow configuration (Requires H01 and Configuration Data Sheet)
Gage Pressure Calibration
Standard Standard
C3 Gage pressure calibration on Rosemount 3051S_CA4 only
Alarm Limit
Standard Standard
C4
(14)(18)
NAMUR alarm and saturation levels, high alarm
C5
(14)(18)
NAMUR alarm and saturation levels, low alarm
C6
(14)(18)
Custom alarm and saturation signal levels, high alarm (Requires C1 and Configuration Data Sheet)
C7
(14)(18)
Custom alarm and saturation signal levels, low alarm (Requires C1 and Configuration Data Sheet)
C8
(14)(18)
Low alarm (standard Rosemount alarm and saturation levels)
Table B-1. 3051S Series Coplanar Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.