Reference Manual
00809-0200-4801, Rev CA
July 2010
Rosemount 3051S
B-14
Backup Link Active Scheduler (LAS)
The transmitter can function as a Link Active Scheduler if the current link master device fails
or is removed from the segment.
Software Upgrade in the Field
Software for the 3051S with F
OUNDATION fieldbus is easy to upgrade in the field using the
F
OUNDATION fieldbus Common Device Software Download procedure.
PlantWeb Alerts
Enable the full power of the PlantWeb digital architecture by diagnosing instrumentation
issues, communicating advisory, maintenance, and failure details, and recommending a
solution.
Advanced Control Function Block Suite
(Option Code A01)
Input Selector Block
Selects between inputs and generates an output using specific selection strategies such as
minimum, maximum, midpoint, average, or first “good.”
Arithmetic Block
Provides pre-defined application-based equations including flow with partial density
compensation, electronic remote seals, hydrostatic tank gauging, ratio control and others.
Signal Characterizer Block
Characterizes or approximates any function that defines an input/output relationship by
configuring up to twenty X, Y coordinates. The block interpolates an output value for a
given input value using the curve defined by the configured coordinates.
Integrator Bock
Compares the integrated or accumulated value from one or two variables to pre-trip and
trip limits and generates discrete output signals when the limits are reached. This block is
useful for calculating total flow, total mass, or volume over time.
Output Splitter Block
Splits the output of one PID or other control block so that the PID will control two valves or
other actuators.
Control Selector Block
Selects one of up to three inputs (highest, middle, or lowest) that are normally connected to
the outputs of PID or other control function blocks.
Fully Compensated Mass Flow Block (Option Code H01)
Calculates fully compensated mass flow based on differential pressure with external process
pressure and temperature measurements over the fieldbus segment. Configuration for the
mass flow calculation is easily accomplished using the Rosemount Engineering Assistant.
Block Execution Time
Resource -
Transducer -
LCD Block -
Analog Input 1, 2 20 milliseconds
PID with Auto-tune 35 milliseconds
Input Selector 20 milliseconds
Arithmetic 20 milliseconds
Signal Characterizer 20 milliseconds
Integrator 20 milliseconds
Output Splitter 20 milliseconds
Control Selector 20 milliseconds