Vista de pagina 79
66
FM-3 Programming Module Reference Manual
Figure 46: Jog Activation
Figure 47: Jog Select Details
If the Jog direction is reversed, the Jog.#.Decel value will be used to decelerate the motor to
zero speed and then the Jog.#.Accel will be used to accelerate to the new (opposite sign)
velocity.
Note
The Jog destinations cannot be initiated when any other motion type (homing, indexing,
or programs) is in progress.
If both jog input functions are “On” there is no motion after a jog deceleration (they
effectively cancel each other). The drive’s display will show “R”, for ready.