Setting Up Parameters
The E Series drive’s input and output lines can be accessed through the removable 10-pin I/
O connector (J6), or through the 44-pin command connector (J5). The FM-3 input and output
lines are located on the front of the FM-3 module.
All inputs and outputs are configured as sourcing and are designed to operate from a +10 to
30 VDC power source. You are responsible for limiting the output current to less than 200
mA for each digital output.
Assignments View
The Assignments View not only displays information but also makes assignments regarding
the source and the destination.
Figure 40: Assignments View
The Assignments View is used to tie a source to a destination. Destinations are functions
that need to be triggered, such as Index Initiates, Program Initiates, Jog Initiates and so
on.
Sources are located on the left side of the Assignment View and reflect events that occur
in the drive. These events are based on drive activity. By expanding individual groups,
you will see more detailed parameters. For example, if you expand the Inputs source
group, you will see DriveInput.1 through ModuleInput.8, as shown in Figure 40. You can
use these events to trigger certain actions (or destinations) on the right side of the view.
To make an assignment in the FM-3 module occur, you must tie a source to a destination.
Any source can be tied to any destination to create the desired system operation.