Setting Up Parameters
Master Velocity
This displays the velocity of the master encoder in master units/second.
Torque Group
Torque Command
This displays the torque command value before it is limited. The torque command may be
limited by either the Torque Limit (if the Torque Limit Enable destination is active) or current
foldback. Units for this parameter are defined in the Torque Group on the User Units View.
Limited Torque
This is the actual torque commanded to the motor. This value is the result after the
TorqueCommand is limited by the current foldback or the TorqueLimit value (if enabled).
Foldback RMS
This parameter accurately models the thermal heating and cooling of the drive and motor.
When it reaches 100 percent, current foldback will be activated. See the Diagnostics section
for an explanation of foldback.
Shunt Power RMS
This parameter models the thermal heating and cooling of the drive internal shunt. This
parameter indicates the percent of shunt capacity utilization. When this value reaches 100
percent, the drive will generate an RMS Shunt Power Fault. This parameter is not applicable
to the EN-204 which does not have an internal shunt resistor. This parameter is applicable to
the EN-208 and EN-214.