63
Setting Up Parameters
Figure 45: Jog Tab
Jog Number
This scroll box allows you to select between Jog0 and Jog1 setup views.
Jog Name
This is a descriptive character string which can be assigned to the specific jog. Giving a name
to a jog can make the motion setup easier to follow.
Time Base
This list box allows the user to select the time base for the individual jog. The options are
Realtime and Synchronized.
Jog Velocity
This parameter specifies the target jog velocity for the individual Jog. The motor will run at
this velocity when jogging with an assignment or through a program. This value is always
positive. The direction of the jog is determined by using the Jog.PlusInitiate or the
Jog.MinusInitiate, which jog in the positive or negative directions respectively.
Jog Acceleration
This is the acceleration ramp used when initiating this individual Jog. If S-Curve ramps are
used, then this is the average acceleration rate for the entire ramp. The units for the
acceleration are setup in the Setup - User Units view in PowerTools FM-3.