Emerson X-web300 Manual de usuario Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 102
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
INDEX
1 GENERAL ADVICE 7
2 GENERAL FEATURES 8
2.1 MAIN FUNCTION 8
3 IC200 L TABLE OF THE FEATURES 10
4 USER INTERFACE 11
4.1 FUNCTION OF THE LEDS OF THE KEY BUTTONS 11
4.2 USE OF THE LED ON THE MODELS VI620 - VI620S REMOTE PANELS 13
4.3 USE OF THE LED ON THE MODELS VI820 - VI820S REMOTE PANELS 13
4.4 KEY FUNCTION 14
4.5 KEY COMBINANTION 15
4.6 LED AND ICONS 15
4.7 DISPLAY AND ICONS 16
4.8 MEANING/ FUNCTIONNING OF THE BOTTOM DISPLAY LED 17
5 REMOTE TERMINAL 17
6 FIRST INSTALLING 17
6.1 ON BOARD CLOCK (OPTIONAL) 17
6.2 RTC SETUP 17
7 WIRING CONNECTIONS 18
7.1 HARDWARE RESOURCES FOR IC260L - IC280L MODELS 18
7.2 HARDWARE RESOURCES FOR IC261L - IC281L MODELS 18
7.3 ANALOG INPUTS NTC – PTC PROBES 19
7.4 DIGITAL INPUTS 19
7.5 ANALOG INPUT FOR PRESSURE TRANSDUCER PP30 (4 ÷ 20MA SIGNAL) 19
7.6 ANALOG INPUT FOR PRESSURE RATIOMETRIC TRANSDUCER PPR30 (0 ÷ 5V SIGNAL) 20
7.7 PWM OUTPUT FOR CONDENSING FAN SPEED CONTROL 20
7.8 FAN CONDENSING CONTROL: 0 ÷ 10VDC OUTPUTS 21
7.9 FAN CONDENSING CONTROL WITH 4÷20MA OUTPUT 21
7.10 PROPORTIONAL OUTPUTS 0 ÷ 10V DUMPER CONTROL 22
7.11 PROPORTIONAL OUTPUTS CONFIGURED FOR AUX RELAY CONTROL 22
7.12 HOT KEY 64 CONNECTION 23
7.13 XJ485 CONNECTION 23
7.14 REMOTE PANELS VI620 – VI820 24
8 ANALOG AND DIGITAL OUTPUT CONFIGURATION 24
8.1 ANALOG INPUT PB1 - PB2 - PB7 - PB8 - PB9 - PB10 24
8.2 ANALOG INPUT CONFIGURATION PB3 - PB4 - PB5 - PB6 25
8.3 DIGITAL INPUT CONFIGURATION ID1 – ID18 25
8.4 DIGITAL OUTPUT (RELAY) CONFIGURATION RL1- RL14 26
8.5 CONDENSER PROPORTIONAL CONTROL CONFIGURATION (2 OUTPUTS) 27
8.6 PROPORTIONAL OUTPUT CONFIGURATION 0 ÷ 10 VDC (4 OUTPUTS) 27
8.7 OTHER OUTPUTS 27
9 TABLE OF THE PARAMETERS 28
10 PROGRAMMING WITH THE “HOT KEY 64” 41
10.1 DOWNLOAD: HOW TO PROGRAM AN INSTRUMENT WITH A PROGRAMMED “HOT KEY” 41
10.2 UPLOAD: HOW TO PROGRAM A “HOT KEY” WITH THE PARAMETERS OF THE INSTRUMENT 42
11 PROGRAMMING USING THE KEYBOARD 42
11.1 PASSWORD DEFAULT VALUES 42
11.2 ENTER THE PR1 - PR2 - PR3 PROGRAMMING LEVELS 42
11.3 HOW TO CHANGE A PARAMETER VALUE 42
11.4 CHANGE THE PASSWORD VALUE 42
11.5 ENTER THE PROGRAMMING LEVEL PR1 43
11.6 ENTER THE PROGRAMMING LEVEL PR2 43
11.7 ENTER THE PROGRAMMING LEVEL PR3 44
11.8 MOVE A PARAMETER LEVEL FROM PR2 TO PR1 44
11.9 MOVE A PARAMETER FROM PR3 TO PR2 TO PR1 45
11.10 VISIBILITY AND PARAMETER VALUE LOCKED 45
11.11 PROGRAMMING: DIGITAL INPUT AND OUTPUT POLARITY 45
11.12 CHANGE THE POLARITY OF THE DIGITAL INPUTS-OUTPUTS 45
12 SELECTION AND START OF THE RUNNING MODE 46
12.1 SELECT THE CHILLER OR THE HEAT PUMP MODE 46
12.2 CHANGE OVER 46
Vista de pagina 1
1 2 3 4 5 6 7 ... 101 102

Comentarios a estos manuales

Vikiyrc 04 Jan 2024 | 11:56:12

urenrjrjkvnm

Evaufi 07 Jan 2024 | 14:53:46

Med