Emerson MICRO MOTION 2700 Manual de instalación Pagina 175

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 264
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 174
Transmitter Configuration and Use: Series 1000 and 2000 Transmitters 165
Enhanced Density Model 2500 CIOModel 1500 ANCalibration
Appendix D
Configuring the Enhanced Density Application
D.1 About this chapter
This appendix describes the configuration procedure for the enhanced density
application.
Note: The enhanced density application is an optional feature of the Series 2000
transmitter, and may not be installed or enabled on your transmitter. To verify that it
is installed, connect to your transmitter using ProLink II, then click on
View/Installed Options.
D.2 Configuration overview
To configure and enable the enhanced density application, the following general steps are required.
1. If you have standard or custom curves (see Section D.3), you may need to load the curve file
onto your transmitter. Instructions are provided in Section D.5.1.
2. If you do not have standard or custom curves, you must configure one or more density curves.
For detailed instructions, see the ProLink II v2.1 manual, available on the Micro Motion web
site, or contact Micro Motion.
3. Specify the active curve. Instructions are provided in Section D.5.2.
4. Perform a density curve trim (optional). Instructions are provided in Section D.6.
Other actions that can be performed include:
Modifying specific curve parameters (see Section D.7)
Saving a curve to a file (see Section D.8)
D.3 Application options – Standard or custom curves
When the enhanced density application is purchased, a set of six standard curves may or may not be
supplied with the application. These curves are described in Table D-1. For information on obtaining
these curves, contact Micro Motion.
In addition, custom curves may be purchased. These curves are defined using customer-supplied data.
Custom curves can be installed at the factory, or the customer can load the purchased curve file(s) into
the transmitter using ProLink II.
CAUTION
Changing configuration can affect transmitter
operation.
Set control devices for manual operation before changing
transmitter configuration.
Model 2500 CIO
Model 2700 AN
Model 2700 IS
Model 2700 CIO
Vista de pagina 174