Specifications and Reference Data
Options (Include with selected model number)
RTD Cable (RTD Sensor must be ordered separately)
Standard Standard
C12 RTD Input with 12 ft. (3.66 m) of Shielded Cable ★
C13 RTD Input with 24 ft. (7.32 m) of Shielded Cable ★
C14 RTD Input with 75 ft. (22.86 m) of Shielded Cable ★
C20
(12)
RTD Input with 27 in. (69 cm) of Armored Shielded Cable ★
C21 RTD Input with 4 ft. (1.22 m) of Armored Shielded Cable ★
C22 RTD Input with 12 ft. (3.66 m) of Armored Shielded Cable ★
C23 RTD Input with 24 ft. (7.32 m) of Armored Shielded Cable ★
C24 RTD Input with 75 ft. (22.86 m) of Armored Shielded Cable ★
C30
(12)
RTD Input with 25 in. (64 cm) of ATEX/IECEx Flameproof Cable ★
C32 RTD Input with 12 ft. (3.66 m) of ATEX/IECEx Flameproof Cable ★
C33 RTD Input with 24 ft. (7.32 m) of ATEX/IECEx Flameproof Cable ★
C34 RTD Input with 75 ft. (22.86 m) of ATEX/IECEx Flameproof Cable ★
C40
(12)
RTD Input with 34 in. (86.36 cm) Shielded Cable and 24 in. (60.96 cm) FM Approved Coupling Flex ★
C41
(12)
RTD Input with 40 in. (101.60 cm) Shielded Cable and 30 in. (76.20 cm) FM Approved Coupling Flex ★
Mounting Brackets
(13)
Standard Standard
B4 Coplanar flange bracket, all SST, 2-in. pipe and panel ★
B1 Traditional flange bracket, Carbon Steel, 2-in. pipe ★
B2 Traditional flange bracket, Carbon Steel, panel ★
B3 Traditional flange flat bracket, Carbon Steel, 2-in. pipe ★
B7 Traditional flange bracket, B1 with SST bolts ★
B8 Traditional flange bracket, B2 with SST bolts ★
B9 Traditional flange bracket, B3 with SST bolts ★
BA Traditional flange bracket, B1, all SST ★
BC Traditional flange bracket, B3, all SST ★
Software Configuration
Standard Standard
C1 Custom software configuration
Note: A Configuration Data Sheet must be completed, see document number 00806-0100-4803.
★
C2 Custom flow configuration
Note: A Custom Fluid Data Sheet must be completed, see document number 00806-0200-4803.
★
C4 NAMUR alarm and saturation levels, high alarm ★
C5 NAMUR alarm and saturation levels, low alarm ★
C6 Custom alarm and saturation signal levels, high alarm ★
C7 Custom alarm and saturation signal levels, low alarm ★
C8 Low alarm (standard Rosemount alarm and saturation levels) ★
Flange Adapter
Standard Standard
D2
(13)
1
/2-14 NPT flange adapter ★
Expanded
D9
(13)
RC
1
/2 SST flange adapter
Ground Screw
Standard Standard
D4 External ground screw assembly ★
Table 1. Rosemount 3051S Scalable MultiVariable transmitter ordering information