9
Reference Manual
00809-0100-4803, Rev DA
Appendix A: Reference Data
April 2013
Specifications and Reference Data
Appendix A Specifications and
Reference Data
Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
Functional specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
Physical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 20
Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 23
Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 27
Exploded view diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 36
Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 37
A.1 Specifications
A.1.1 Performance Specifications
For zero-based spans, reference conditions, silicone oil fill, glass-filled PTFE o-rings, SST
materials, or Coplanar flange digital trim values set to equal range points.
Conformance to specification (±3 (Sigma))
Technology leadership, advanced manufacturing techniques, and statistical process control
ensure measurement specification conformance to ±3or better.
Reference Accuracy
(1)
Models Classic MV Ultra for Flow
3051SMV_ _1: Differential Pressure, Static Pressure, & Temperature
3051SMV_ _2: Differential Pressure & Static Pressure
DP Ranges 2 - 3 ±0.04% of span;
For spans less than 10:1,
±0.04% of reading up to 8:1
DP turndown from URL;
±[0.04 + 0.0023
(URL/RDG
(3)
)]% reading to
200:1 DP turndown from
URL
(4)
DP Range 1 ±0.10% of span;
For spans less than 15:1,
N/A
AP and GP
Ranges 3 - 4
±0.055% of span;
For spans less than 10:1,
±0.025% of span;
For spans less than 10:1,
Process Temp.
RTD Interface
(2)
±0.67 °F (0.37 °C) ±0.67 °F (0.37 °C)
0.01 0.004+
URL
span
--------------
% of span
0.025 0.005+
URL
span
--------------
% of span
0.0065
URL
span
--------------
% of span
0.004
URL
span
--------------
% of span
Comentarios a estos manuales