29
Reference Manual
00809-0100-4803, Rev DA
Appendix A: Reference Data
April 2013
Specifications and Reference Data
Process Connection Size
Material Type
Flange
Material
Drain Vent Bolting
F25
(8)
Traditional flange RC
1
/4 SST Alloy C-276 ★
F52
DIN-compliant
traditional flange
1
/4–18 NPT SST 316 SST
7
/16-in. bolting ★
G11 Vertical mount level
flange
2-in. ANSI class 150 SST ★
G12 Vertical mount level
flange
2-in. ANSI class 300 SST ★
G14
(8)
Vertical mount level
flange
2-in. ANSI class 150 Cast C-276 ★
G15
(8)
Vertical mount level
flange
2-in. ANSI class 300 Cast C-276 ★
G21 Vertical mount level
flange
3-in. ANSI class 150 SST ★
G22 Vertical mount level
flange
3-in. ANSI class 300 SST ★
G31 Vertical mount level
flange
DIN- DN 50 PN 40 SST ★
Expanded
EB6 Assemble to Primary Element with Manifold and Coplanar Flange, CS, Alloy C-276
F32 Bottom vent traditional
flange
1
/4–18 NPT SST 316 SST
F42 Bottom vent traditional
flange
RC
1
/4 SST 316 SST
F62 DIN-compliant
traditional flange
1
/4–18 NPT SST 316 SST M10 bolting
F72 DIN-compliant
traditional flange
1
/4–18 NPT SST 316 SST M12 bolting
G41 Vertical mount level
flange
DIN- DN 80 PN 40 SST
Transmitter Output
Standard Standard
A 4–20 mA with digital signal based on HART protocol ★
Housing Style Material Conduit Entry Size
Standard Standard
1A PlantWeb housing Aluminum
1
/2–14 NPT ★
1B PlantWeb housing Aluminum M20 x 1.5 ★
1J PlantWeb housing SST
1
/2–14 NPT ★
1K PlantWeb housing SST M20 x 1.5 ★
Expanded
1C PlantWeb housing Aluminum G
1
/2
1L PlantWeb housing SST G
1
/2
Table 1. Rosemount 3051S Scalable MultiVariable transmitter ordering information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.