Stan dard fea tures - all sys tems (con tin ued)
Filters
The direct expansion filter is EU3 (G3) and is located within
the cabinet before the evaporating coil. The filter provides
filtration of both the recirculated and the fresh air to obtain the
required degree of air cleanliness in the room. The filters can
be removed from the front of the unit (outdoor) by opening the
front panel.
The filters are 48mm deep on models LEX04/05/06E and
60mm deep on models LEX08/10/14E. The filters are pleated
air filters, specially designed to minimise the air pressure drop
and improve efficiency.
Electric panel
The electrical panel is housed in a secure compartment
isolated from the air stream, and is in compliance with EN
60204-1. The panel contains the controller PCB, MCBs for
individual components and contactors.
A mains MCB is supplied as standard. A single phase
transformer powers the 24 V rail to the controller. Automatic
restart is provided as standard.
Controls
The Mi cro face en vi ron mental con trol sys tem is
mi cro proc es sor based and can be pro grammed to match the
unique needs of any ap pli ca tion. The proc es sor in te grates the
sepa rate me chani cal and elec tri cal com po nents into a
‘state -of -the -art’ con di tioned space sup port sys tem that
con trols and moni tors tem pera ture, air flow and air
clean li ness.
The con trol sys tem of fers a tai lored and well proven ad vance
in re li abil ity and con trol flexi bil ity al low ing the unit to
mod ify its per form ance in re sponse to chang ing criti cal space
con di tions.
The con trol ler al lows lo cal moni tor ing and pro gram ming of
the fol low ing room con di tions:
Tem pera ture (
o
C)
Tem pera ture set point (5.0
o
C – 40.0
o
C in steps of 0.1
o
C)
Tem pera ture sen si tiv ity (1.0
o
C - 10
o
C in steps of 0.1
o
C)
The parameters are enunciated using symbols and text on an
LCD display. Nor mal op er at ing modes are in di cated by
sym bols on the dis play. Alarm con di tions ac ti vate a vis ual
in di ca tor.
The fol low ing alarms are stan dard:
High temperature
Low temperature
Fan failure
High pressure alarm
Low pressure alarm
Electrical reheat high temperature
Memory failure
Common alarm
For a full list of all the op tions and alarms avail able with the
Mi cro face con trol ler, re fer to the Mi cro face Con trol ler
Op era tion Man ual (P/N SLE MF OM).
The con trol ler also in cor po rates a se quen tial auto- restart
timer, al low ing field ad just able time de lays to be ap plied to
unit re start af ter a power loss (or other shut down). The tim ers
al low mul ti ple units to be re started while lim it ing
in stan ta ne ous in rush cur rent.
A volt-free warning contact is available for remote indication
of High Temperature, Low Temperature and Reheat
Overtemperature.
A further contact is available for remote indication of High
Pressure, Low Pressure, Fan Failure and Controls Failure.
Fresh air free cooling
Fresh air free cooling consists of a hinged damper plate and
motorised actuator. When ambient temperatures permit,
compressorised cooling will be deactivated and cool outside
ambient air is diverted directly to the conditioned space to
provide “free” cooling.
Refrigerant
R22 HCFC is the standard refrigerant used in the InteleCool
EX range. An optional “Zero ODP” refrigerant, R407C is
available to special order.
Packaging
As standard, the units are wrapped in bubble-wrap to protect
painted surfaces, enclosed in a cardboard box and mounted on
a wooden pallet.