ZX Platform Condensing Unit User Manual

Pagina 2

7Electrical ConnectionPower supply The ZX condensing unit electrical connection to the power supply must be made by qualified technicians, who should

Pagina 3

8ZX Platform Condensing Unit Refrigeration connections Refrigeration piping installation All interconnecting pipes should be of refrigeration grade, c

Pagina 4 - ZX Platform CDU

9Location and fixing The unit should always be installed in a location that ensures clean air flow. It is recommended that a clearance of 300 mm from

Pagina 5 - - “ACC” indicates accessory

10ZX Platform Condensing Unit Start Up and Operation(1 second)->- Power On- Unit Identification Code- Software Version No.(3 seconds)->(3 second

Pagina 6 - Physical Layout

11Alarm messaging - Digital scroll controller (ZXD)Alarm Mode Set Points Controller Actions Reset RemarksdtLDLT >= dtL after dLd time delay- Compre

Pagina 7 - Product Specication

12ZX Platform Condensing Unit BLUEZX Condensing Unit Wiring DiagramPFJ: 220V-50 Hz -1Ph ATTENTION: Unit MUST be grounded!

Pagina 8

135.Only ZXL TF5 has 4 additional posts on the terminal block.ZX/ZXL Condensing Unit Wiring DiagramTFD: 380V/420V -50 Hz-3PhTF7: 380V-60 Hz -3PhATTENT

Pagina 9 - Figure 06

14ZX Platform Condensing Unit ZX/ZXL Condensing Unit Wiring DiagramTF5: 200/230V- 50 Hz/ 60 Hz - 3PhATTENTION: Unit MUST be grounded!

Pagina 10 - Installation

15ZXD Condensing Unit Wiring Diagram (With Fan Speed Control Function)TFD - 380/420V, 50Hz, 3PhTF7 - 380V, 60Hz, 3Ph052-2662-002012-02-159 11 N10 NNTe

Pagina 11

16ZX Platform Condensing Unit ZXD Condensing Unit Wiring Diagram (Without Fan Speed Control Function)TFD - 380/420V, 50Hz, 3PhTF7 - 380V, 60Hz, 3Ph052

Pagina 13

Asia 02 A01 10 – R00 Issued 4/2012Emerson, Copeland PerformanceAlert and Copeland Scroll are trademarks of Emerson Electric Co. or one of its afliate

Pagina 15

1ZX Platform CDUDisclaimer Thank you for purchasing the ZX platform condensing unit from Emerson Climate Technologies. ZX platform CDUs are the best i

Pagina 16 - TF7: 380V-60 Hz -3Ph

2ZX Platform Condensing Unit Proprietary Electronic Algorithms to Control Fan Speed, Optimizing Energy Performance for Local Seasonal Ambient Temperat

Pagina 17

3Physical LayoutThe following figures give an introduction to the physical layout of the ZX Platform CDU.ZX- MT, ZXL-LT E2 Controller* ZXD Digital Scr

Pagina 18 - Controller

4ZX Platform Condensing Unit ZX ZXD ZXLModel BOM Model BOM Model BOM401 451 ALL ALLZX0200/E1.181.68ZXL0200/E 1.06ZX0250/E1.331.83ZXL0250/E 1.06ZX0

Pagina 19

5E2 Control Board - Rotary Switch And Dip Switch Setting (ZX-MT & ZXL-LT)ModelRotary Switch3-Bit No. 32-Bit 1/2ZX0200/E-PFJ 7 OFF ON/ONZX0250/E-PF

Pagina 20 - EmersonClimate.com/Asia

6ZX Platform Condensing Unit Digital Scroll controller (ZXD)The controller has been pre-programmed with a number of parameter values that are set for