Figure 38. Fisher 4320 Assembly
ON/OFF CONTROL OPTION
NOTE:
KEY 31 AND 43 NOT SHOWN
GE53345
Spool Valve and Pneumatic Gasket Installation
1. Align the five small holes on the gasket (key 16) with the five small holes on the spool valve (key 17). Inserting two
or more of the hex socket cap screws (key 18) through the spool can help to align the gasket with the spool.
2. Install the spool onto the housing, making sure that the side of the spool with three 1/4 NPT fittings is visible from
the front of the device.
3. Replace the remaining hex socket cap screws (key 18); tighten to a torque of 4.5 N•m (40 lbf•in).
Pneumatic Interface and Gasket Removal
1. Follow the above instructions to remove the spool valve and pneumatic gasket
2. Open the 4320 and carefully unplug the two red pilot valves connectors, shown in figure 39, from the sensor board.