Vista de pagina 40
A-5
EN
Rosemount Inc
Ambient Temperature Effect
Transmitters can be installed in locations where the ambient temperature is
between 40 and 85 °C (40 and 185 °F).
Sensor Options
Temperature Effects per
1.0 °C(1.8°F) Change in
Ambient Temperature
(1)
(1) Change in ambient is with reference to the calibration temperature of the transmitter 68 °F(20°C) from
factory.
Ranges D/A Effect
2-, 3-, 4-Wire RTDs
Pt 100
(
α = 0.00385)
0.003 °C (0.0054 °F)
Entire sensor input range 0.001% of span
PT 100
(
α = 0.003916)
0.003 °C (0.0054 °F)
Entire sensor input range 0.001% of span
Pt 200 0.004 °C (0.0072 °F)
Entire sensor input range 0.001% of span
Pt 500 0.003 °C (0.0054 °F)
Entire sensor input range 0.001% of span
Pt 1000 0.003 °C (0.0054 °F)
Entire sensor input range 0.001% of span
Ni 120 0.003 °C (0.0054 °F)
Entire sensor input range 0.001% of span
Cu 10 0.03 °C (0.054 °F)
Entire sensor input range 0.001% of span
Thermocouples
Typ e B 0.014 °C
0.032 °C (0.0025% of
(R 300))
0.054 °C (0.011% of
(R 100))
R 1000°C
300 °C
R < 1000 °C
100 °C
R< 300 °C
0.001% of span
Typ e E 0.005 °C+(0.00043%ofR) All
0.001% of span
Typ e J 0.0054 °C +(0.0029%of R)
0.0054 °C + (0.0025% of
absolute value R)
R0 °C
R<0°C
0.001% of span
Typ e K 0.0061 °C +(0.00054% of R)
0.0061 °C + (0.0025% of
absolute value R)
R
0 °C
R<0°C
0.001% of span
Typ e N 0.0068 °C +(0.00036% of R) All
0.001% of span
Type R, S, W5Re/
W26Re
0.016 °C
0.023 °C (0.0036% of R)
R 200°C
R<200°C
0.001% of span
Typ e T 0.0064 °C
0.0064 °C +(0.0043% of
absolute value R)
R0 °C
R<0°C
0.001% of span
DIN Type L 0.0054 °C + (0.00029%
of R)
0.0054 °C +(0.0025% of
absolute value R)
R
0 °C
R<0°C
0.001% of span
DIN Type U 0.0064 °C
0.0064 °C +(0.0043% of
absolute value R)
R0 °C
R<0°C
0.001% of span
Millivolt Input 0.0005 mV
Entire sensor input range 0.001% of span
2-, 3-, 4-Wire Ohm Input0.0084
Entire sensor input range 0.001% of span