Table 4-3 provides a guide to diagnostic messages used by the Model 275 HART
Communicator (HC).
Variable parameters within the text of a message are indicated with the notation
<variable parameter>.
Reference to the name of another message is identified by the notation [another
message].
TABLE 4-3. Model 275 HART Diagnostics Messages
Message Description
Add item for ALL device
types or only for this ONE
device type
Asks the user whether the hot key item being added should be
added for all device types or only for the type of device that is
connected.
Command Not
Implemented
The connected device does not support this function.
Communication Error Either a device sends back a response indicating that the message
it received was unintelligible, or the HC cannot understand the
response from the device.
Configuration memory
not compatible with
connected device
The configuration stored in memory is incompatible with the device
to which a transfer has been requested.
Device Busy The connected device is busy performing another task.
Device Disconnected Device fails to respond to a command.
Device write protected Device is in write-protect mode. Data can not be written.
Device write protected.
Do you still want to shut
off?
Device is in write-protect mode. Press YES to turn the HC off and
lose the unsent data.
Display value of variable
on hotkey menu?
Asks whether the value of the variable should be displayed
adjacent to its label on the hotkey menu if the item being added to
the hotkey menu is a variable.
Download data from
configuration memory to
device
Prompts user to press SEND softkey to initiate a memory to device
transfer.
Exceed field width Indicates that the field width for the current arithmetic variable
exceeds the device- specified description edit format.
Exceed precision Indicates that the precision for the current arithmetic variable
exceeds the device- specified description edit format.
Ignore next 50
occurrences of status?
Asked after displaying device status. Softkey answer determines
whether next 50 occurrences of device status will be ignored or
displayed.
Illegal character An invalid character for the variable type was entered.