Reference Manual
00809-0100-4801, Rev FA
October 2010
A-25
Rosemount 3051S Series
Expanded
1C PlantWeb housing Aluminum G
1
/2
1L PlantWeb housing SST G
1
/2
2C Junction Box housing Aluminum G
1
/2
2G Junction Box Housing with output for remote display and interface Aluminum G
1
/2
Wireless Options (Requires option code X and wireless PlantWeb housing)
Update Rate
Standard Standard
WA User Configurable Update Rate ★
Operating Frequency and Protocol
Standard Standard
3 2.4 GHz DSSS, IEC 62591 (WirelessHART) ★
Omnidirectional Wireless Antenna
Standard Standard
WK External Antenna ★
WM Extended Range, External Antenna ★
SmartPower
™
Standard Standard
1
(12)
Compatible with Black Power Module (I.S. Power Module Sold Separately) ★
Other Options (Include with selected model number)
PlantWeb Control Functionality
Standard Standard
A01
(13)
FOUNDATION fieldbus Advanced Control Function Block Suite ★
PlantWeb Diagnostic Functionality
Standard Standard
D01
(13)
FOUNDATION fieldbus Diagnostics Suite ★
DA2
(13)(14)
Advanced HART Diagnostics Suite ★
PlantWeb Enhanced Measurement Functionality
Standard Standard
H01
(13)(15)
FOUNDATION fieldbus Fully Compensated Mass Flow Block ★
Mounting Bracket
(16)
Standard Standard
B4 Coplanar flange bracket, all SST, 2-in. pipe and panel ★
B1 Traditional flange bracket, CS, 2-in. pipe ★
B2 Traditional flange bracket, CS, panel ★
B3 Traditional flange flat bracket, CS, 2-in. pipe ★
B7 Traditional flange bracket, B1 with SST bolts ★
B8 Traditional flange bracket, B2 with SST bolts ★
B9 Traditional flange bracket, B3 with SST bolts ★
BA Traditional flange bracket, B1, all SST ★
BC Traditional flange bracket, B3, all SST ★
Software Configuration
Standard Standard
C1
(17)
Custom software configuration (Requires Configuration Data Sheet) ★
C2 Custom flow configuration (Requires H01 and Configuration Data Sheet) ★
Gage Pressure Calibration
Standard Standard
C3 Gage pressure calibration on Rosemount 3051S_CA4 only ★
Alarm Limit
Standard Standard
C4
(13)(17)
NAMUR alarm and saturation levels, high alarm ★
C5
(13)(17)
NAMUR alarm and saturation levels, low alarm ★
C6
(13)(17)
Custom alarm and saturation signal levels, high alarm (Requires C1 and Configuration Data Sheet) ★
C7
(13)(17)
Custom alarm and saturation signal levels, low alarm (Requires C1 and Configuration Data Sheet) ★
C8
(13)(17)
Low alarm (standard Rosemount alarm and saturation levels) ★
Table A-1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.