Reference Manual
00809-0100-4801, Rev FA
October 2010
Rosemount 3051S Series
7-42
Figure 7-32. Configure (Guided Setup and Manual Setup) Menu Tree
Home
1 Overview
2 Configure
3 Service Tools
Configure
1 Guided Setup
2 Manual Setup
3 Alert Setup
(see Figure 7-33)
Guided Setup
1 Initial Setup
2 Diagnostics Setup
3 Optional Configuration
Manual Setup
1 Process Variables
2 Analog Output
3 Scaled Variable
4 Display Options
5 HART
6 Security
7 Device Information
Initial Setup
1 Basic Setup
2 Zero Trim
Diagnostics Setup
1 Statistical Process Monitoring
2 Power Advisory
3 Process Alerts
4 Service Alert
Optional Configuration
1 Configure Display
2 Configure Burst Mode
Basic Setup
1 Device Tagging
2 Units of Measure
3 Pressure Damping
4 Variable Mapping
5 Analog Output
6
Config Alarm & Saturation Levels
Display Options
1 Pressure: On or Off
2 Scaled Variable: On or Off
3 Module Temperature: On or Off
4 Percent of Range: On or Off
5 Standard Deviation: On or Off
6 Mean: On or Off
7 Coefficient of Variation: On or Off
Process Variables
1 Pressure Setup
2 Module Temperature Setup
Analog Output
1 Set Range Points
2 Set Range Points Manually
3 Sensor Limits
4 Readings
5 Alarm and Saturation Levels
Pressure Setup
1 Pressure
2 Units
3 Damping
4 Transfer Function
Module Temperature Setup
1 Module Temperature
2 Units
Set Range Points
1 PV Upper Range Value
2 PV Lower Range Value
3 Primary Variable
Set Range Points Manually
1 Range By Applying Pressure
Sensor Limits
1 Upper
2 Lower
3 Minimum Span
Readings
1 Analog Output
2 Percent of Range
Alarm and Saturation Levels
1 Alarm Direction
2 High Alarm
3 High Saturation
4 Low Saturation
5 Low Alarm
6 Config Alarm & Saturation Levels
Scaled Variable Setup
1 Scaled Variable
2 Units
3 Transfer Function
4 Linear Options*
5 Configure Scaled Variable
*If Square Root is selected for Transfer Function,
"Square Root Options"
Linear Options
1 Offset
Square Root Options
1 Cutoff Mode
2 Low Flow Cutoff
Display
1 Display Options
Display Options
1 Pressure: On or Off
2 Scaled Variable: On or Off
3 Module Temperature: On or Off
4 Percent of Range: On or Off
5 Standard Deviation: On or Off
6 Mean: On or Off
7 Coefficient of Variation: On or Off
HART
1 Variable Mapping
2 Burst Mode Configuration
3 Communication Settings
Variable Mapping
1 Primary Variable
2 2nd Variable
3 3rd Variable
4 4th Variable
Burst Mode Configuration
1 Mode
2 Option
Communication Settings
1 Polling Address
Security
1 Write Protect Status
2 Local ZERO/SPAN Buttons
Device Information
1 Identification
2 Flange Information
3 Remote Seal Information
Identification
1 Tag
2 Model
3 Date
4 Descriptor
5 Message
6 Transmitter Serial Number
7 Model Numbers
Flange Information
1 Process Connection
2 Process Connection Material
3 O-ring Material
4 Drain/Vent Material
Remote Seal Information
1 Number
2 Type
3 Diaphragm Material
4 Fill Fluid