Emerson 1410 Manual de servicio Pagina 201

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 222
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 200
Safety Notes
AXP 1410 Installation and Use (6806800H70D)
201
System Damage Munich
Running the system longer than 30 seconds with less than three fans damages the system.
If you exchange a fan (three remaining operating fans) ensure that the exchange procedure is
finished within 30 seconds.
System Damage
A torn filter is ineffective in trapping particulates and will interrupt air flow distribution.
Before returning a filter to service, visually inspect it for tears or rips that may have occurred
during cleaning. Do not reinstall a torn filter. You may order replacement fan filters by
contacting your Emerson sales representative.
System Damage and Personal Injury
Fans may continue to rotate after power is removed. When exchanging a fan, rotating blades
in the fan may be exposed.
To prevent injury keep fingers and tools away from rotating blades in the fan.
System Alarm
Bouncing the FTM during insertion may cause an alarm condition in the system.
Insert the FTM with a single, steady motion and do not force the module into the slot.
Pin Damage
Forcing the FTM into the system may damage connector pins.
To avoid crushing or bending the connector pins, back the module out and insert it again if it
hangs during insertion.
System Damage
Replacement of a PEM must be executed according to the recommended service interval of xx
minutes and be performed by a skilled service technician.
Personal Injury
To avoid electric shock verify that the system is powered off and that all power sources are
disconnected before servicing any components internal to the system.