FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
165
7.3.6.3 Circuit Breaker State Sensors
The following tables describe the OEM circuit breaker state sensors available on the PEM.
Threshold access support
Event Message Control Entire Sensor Only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
Reading Type According to PICMG 3.0
Table 7-50 Sensor No. 1, IPMB Physical (continued)
Feature Raw Value/Description Interpreted Value
Table 7-51 Sensor No. 5, CB 1
Feature Raw Value/Description Interpreted Value
Sensor Name CB 1
Type of Measurement Monitors if the circuit breaker has been
opened.l
Class Discrete
Event/Reading Type 0x03 Digital Discrete
Sensor Type 0xC0 OEM-reserved
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm Mode Auto
Event Message Control Entire Sensor only