Emerson 1410 Manual de servicio Pagina 127

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 222
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 126
FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
127
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xDB, 0xDA, 0xD9 (11.8260, 11.7720, 11.7180) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xF7, 0xF9, 0xFA (13.3380, 13.4460, 13.5) Volts
Table 7-4 Sensor No. 5 +3.3V
Feature Raw Value/Description Interpreted Value
Sensor Name +3.3V
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xD8, 0xD4, 0xD1 (3.1104, 3.0528, 3,0096) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xF4, 0xF7, 0xFA (3.5136, 3.5568, 3.6) Volts
Table 7-3 Sensor No. 4 +12V B_MON (continued)
Feature Raw Value/Description Interpreted Value
Vista de pagina 126
1 2 ... 122 123 124 125 126 127 128 129 130 131 132 ... 221 222

Comentarios a estos manuales

Sin comentarios