FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
129
7.2.2.2 Temperature Sensors
The following sensors measure temperatures of the FTM.
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xDF, 0xD5, 0xC8 (4.8168, 4.6008, 4.3200) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xF1, 0xF6, 0xFA (5.2056, 5.3136, 5.4) Volts
Table 7-6 Sensor No. 7 +5V B_MON (continued)
Feature Raw Value/Description Interpreted Value
Table 7-7 Sensor No. 30 FTM Temp 1
Feature Raw Value/Description Interpreted Value
Sensor Name FTM Temp 1
Device
Sensor Type 0x01 Temperature
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable