FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
128
Table 7-5 Sensor No. 6 +5V A_MON
Feature Raw Value/Description Interpreted Value
Sensor Name +5V A_MON
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xDF, 0xD5, 0xC8 (4.8168, 4.6008, 4.3200) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xF1, 0xF6, 0xFA (5.2056, 5.3136, 5.4) Volts
Table 7-6 Sensor No. 7 +5V B_MON
Feature Raw Value/Description Interpreted Value
Sensor Name +5V B_MON
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Vista de pagina 127