Reference Manual
00809-0600-4026, Rev BA
December 2011
Rosemount Process Radar
6-2
INSTALLATION &
CONFIGURATION
Step 1. Complete the QIG Follow the instructions provided in Section 5: 5400 Quick Installation Guide.
Step 2. Basic
Configuration
Basic Configuration Parameters
• HART/FF Address and Device Tag
• Measurement Units
Figure 6-1. Tank Geometry
• Tank Height
• Tank Type and Tank Bottom Type
• Pipe Diameter if applicable
• Hold Off/Upper Null Zone
This parameter should only be changed if there are disturbing objects
close to the antenna, e.g. nozzle disturbances. No valid measurements
are possible above the Hold Off Distance.
• Process Conditions
For best performance, select only if applicable, and no more than two
options.
• Product Dielectric Range
• Volume Configuration, if needed
• Analog Output (HART)
Tank Height (R)
Product Level
Upper Reference Point
Lower Reference Point
(Level=0)
Transition Zone