47
Reference Manual
00809-0100-4102, Rev AA
Section 3: Installation
May 2013
Installation
Figure 3-14. Optional LCD Display
3.5 Rosemount 304, 305 and 306 integral manifolds
The Rosemount 305 Integral Manifold mounts directly to the transmitter and is available in two
designs: Traditional and Coplanar. The traditional 305 Integral Manifold can be mounted to
most primary elements with mounting adapters in the market today. The Rosemount 306
Integral Manifold is used with Rosemount 2051T In-line transmitters to provide block-and-bleed
valve capabilities of up to 10000 psi (690 bar). The Rosemount 304 comes in two basic styles:
traditional (flange x flange and flange x pipe) and wafer. The 304 traditional manifold comes in
2, 3, and 5-valve configurations. The 304 wafer manifold comes in 3 and 5 valve configurations.