Emerson FM-3 Guía de usuario Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 263
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
10
Epsilon Eb and EN Drives Reference Manual
negative changes to the Pulse Position Input. All edges of A and B are counted, therefore one
revolution of a 2048 line encoder will produce an 8192 count change on the Pulse Position
Input.
Figure 5: Pulse/Quadrature Signals, + Command
Figure 6: Pulse/Quadrature Signals, – Command
Pulse/Pulse Interpretation
In Pulse/Pulse interpretation, pulses received on the A channel are interpreted as positive
changes to the Pulse Position Input. Pulses received on the B channel are interpreted as
negative changes to the Pulse Position Input.
Figure 7: Pulse/Pulse Signals, Differential Inputs
Vista de pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 262 263

Comentarios a estos manuales

Sin comentarios