122
Epsilon Eb and EN Drives Reference Manual
Figure 100: Operating Mode, Velocity Mode Selected
3. Enter a “Full Scale Velocity” value. The velocity is equal to the Analog Full Scale
parameter which is defaulted to a 10V analog command.
Velocity Presets Submode Setup
1. Select the “Velocity Mode” radio button from the Operating Mode group.
2. Select the “Presets” submode radio button from the Submode group.
Figure 101: Velocity Submode, Velocity Presets
3. Select the desired “Velocity Preset” number.
4. Enter a "Velocity Preset" for each "Preset Number" being used.
5. Enter an “Accel/Decel Presets” value for each "Preset Number" being used.
6. Click on the Inputs tab. Assign the “Velocity Preset Line #1” and “Velocity Preset Line
#2” functions to input lines by highlighting the function then selecting one of the “Input
Line Selection” radio buttons or by dragging the highlighted preset to the desired input
lines.
7. The Velocity Preset Input functions can be made Always Active or Active Off by using
the respective check box.
Velocity Summation Submode Setup
1. Select the “Velocity Mode” radio button from the Operating Mode group.
2. Select the “Summation” submode radio button from the Submode group.