Product Data Sheet
00813-0100-4530, Rev AA
Catalog 2008 - 2009
Rosemount 5300 Series
Level-18
Electric
Power Supply HART
®
: 16-42.4 V dc (16-30 V dc in IS applications, 20-42.4 Vdc in Explosionproof /
Flameproof applications).
F
OUNDATION™ fieldbus: 9-32 V dc (9-30 V dc in IS applications, and 16-32 V dc in
Explosionproof / Flameproof applications).
FISCO, IS applications: 9-17.5 V dc.
Internal Power Consumption < 50 mW in normal operation.
Output HART
®
4-20 mA current loop or FOUNDATION™ fieldbus.
Quiescent Current Draw ( FOUNDATION™
fieldbus)
21 mA
Signal on Alarm Standard : Low = 3.75 mA, High = 21.75 mA.
Namur NE 43: Low = 3.60 mA, High = 22.50 mA.
Saturation Levels Standard: Low = 3.9 mA, High = 20.8 mA.
Namur NE 43: Low = 3.8 mA, High = 20.5 mA.
IS Parameters See “Product Certifications” on page 21
Cable Entry ½ - 14 NPT for cable glands or conduit entries.
Optional: M20 x 1.5 conduit / cable adapter, M12 4-pin male eurofast
®
connector or A size
Mini 4-pin male minifast
®
connector.
Output Cabling Twisted shielded pairs, 18-12 AWG.
Mechanical
Probes Coaxial: 1.3 ft (0.4 m) to 19.7 ft (6 m).
Rigid Twin Lead: 1.3 ft (0.4 m) to 9.8 ft (3 m).
Flexible Twin Lead: 3.3 ft (1 m) to 164 ft (50 m).
Rigid Single Lead: 1.3 ft (0.4 m) to 9.8 ft (3 m).
Flexible Single Lead: 3.3 ft (1 m) to 164 ft (50 m).
For further information, see the probe table on page 10.
Tensile Strength 4 mm Flexible Single Lead probe (model code 5A, 5B): 2698 lb (12 kN)
6 mm Flexible Single Lead probe (model code 6A, 6B): 6519 lb (29 kN)
Flexible Twin Lead probe: 2023 lb (9 kN).
Collapse Load 4 mm Flexible Single Lead probe (model code 5A, 5B): 3597 lb (16 kN)
6 mm Flexible Single Lead probe (model code 6A, 6B): 7868 lb (35 kN)
Sideway Capacity Coaxial: 73.7 ft lbf or 3.7 lb at 19.7 ft (100 Nm or 1.67 kg at 6 m).
Rigid Twin Lead: 2.2 ft lbf or 0.22 lb at 9.8 ft (3 Nm or 0.1 kg at 3 m).
Rigid Single Lead: 4.4 ft lbf or 0.44 lb at 9.8 ft (6 Nm or 0.2 kg at 3 m).
Material Exposed to Tank Atmosphere • 316 / 316L SST (EN 1.4404), PTFE, PFA
(3)
and O-ring materials (model code 1) or
• Hastelloy
®
C-276 (UNS N10276), PTFE, PFA
(3)
and O-ring materials (model code 2) or
• Monel
®
400 (UNS N04400), PTFE, PFA
(3)
and O-ring materials (model code 3)
• PTFE
(4)
(model code 7) or
• PTFE
(4)
, 316 L SST (EN 1.4404) and O-ring materials (model code 8)
• 316L SST (EN 1.4404), Ceramic (Al
2
O
3
), Graphite (HTHP Probe, model code H)
• 316L SST (EN 1.4404), Ceramic (Al
2
O
3
), Graphite, PFA (HP Probe, model code P)
See “Ordering Information” on page 32.
Dimensions See “Dimensional Drawings” on page 23.
Probe Angle 0 to 90 degrees.
Housing / Enclosure Polyurethane-covered Aluminum.
Flanges, Threads See “Tank Connection” on page 7 and “Ordering Information” on page 32.
Height Above Flange See “Dimensional Drawings” on page 23.
Weight Transmitter Head (TH): 4.4 lbs (2 kg). Flange: depends on flange size.
Coaxial probe: 0.67 lbs/ft (1 kg/m).
Rigid Single Lead probe: 0.27 lbs/ft (0.4 kg/m).
Rigid Twin Lead probe: 0.40 lbs/ft (0.6 kg/m).
Flexible Single Lead probe: 0.05 lbs/ft (0.08 kg/m).
Flexible Twin Lead probe: 0.09 lbs/ft (0.14 kg/m).
End weight: 0.88 lbs (0.40 kg) for the 4 mm single lead probe, 1.2 lbs (0.55 kg) for the 6 mm
single lead probe and 1.3 lbs (0.60 kg) for twin lead probes.