Product Interfaces
Control Valve Interface
The DVC6200 SIS digital valve controller is mechanically attached to the valve’s actuator by means of a mounting
bracket. The valve's position is conveyed to the travel sensor of the DVC6200 SIS digital valve controller by means of
the feedback bracket and magnet assembly attached to the actuator’s stem.
MOUNTING
BRACKET
ACTUATOR
DVC6200 SIS
DIGITAL VALVE
CONTROLLER
FEEDBACK BRACKET
AND MAGNET ASSEMBLY
X0381-1
Pneumatic tubing connected to the DVC6200 SIS brings instrument supply air to the DVC6200 SIS and takes
controlled output air from the DVC6200 SIS to the actuator. Pressure sensors in the DVC6200 SIS measure these
pressure signals and present them as device variables
Host interface
The input to the DVC6200 SIS can either be twowire 4to20 mA current loop (in pointtopoint mode) or 24 VDC (in
multidrop mode). This input is connected in the DVC6200’s terminal box on two terminals marked “LOOP +” and
“LOOP ”. Refer to the DVC6200 Series quick start guide for connection details.
Pushbutton Calibration
A pushbutton near the wiring terminals in the terminal box provides a quick means to autocalibrate the travel of the
instrument. The button must be pressed for 3 to 10 seconds. Autocalibration will move the valve through the full
range of travel whether the Instrument Mode is In Service or Out of Service. However, if the Write Protection is
Protected, this button will not be active. To abort, press the button again for 1 second. The calibration button is
disabled by default.