Product Data Sheet
PS-00374, Rev. S
September 2011
Micro Motion
®
ELITE
®
Coriolis meters are the leading precision flow and
density measurement solutions. ELITE meters offer the most accurate and
repeatable measurement available for liquids, gases, or slurries.
Best precision flow and density measurement
Unique design delivers unparalleled measurement sensitivity and stability
Guarantees consistent, reliable performance over the widest flow range
Smart Meter Verification for quick, complete meter diagnosis without
process interruption.
2-wire loop-powered option for installation simplification
Superior performance in the most challenging applications
Industry standard for custody transfer and critical process control
Best two-phase flow capability for batching, loading, and entrained
air applications
Immune to fluid, process, or environmental effects for superb
measurement confidence
High performance
compact drainable
Coriolis meter
Peak performance
Coriolis meter
Hygienic compact
drainable Coriolis
meter
Straight tube
full-bore
Coriolis meter
General purpose
flow-only
Coriolis meter
F-Series
ELITE
®
H-Series
T-Series
R-Series
Extreme low-
flow Coriolis
meter
LF-Series
Micro Motion
®
ELITE
®
Coriolis Flow and Density Meters
Peak performance
high capacity
meter
ELITE HC
Vista de pagina 0
1 2 3 4 5 6 ... 59 60

Indice de contenidos

Pagina 1 - Micro Motion

Product Data SheetPS-00374, Rev. SSeptember 2011Micro Motion® ELITE® Coriolis meters are the leading precision flow and density measurement solutions.

Pagina 2 - Contents

10 Micro Motion® ELITE® Flow and Density MetersPressure ratings continued Sensor pressure/temperature rating with ASME B16.5 UNS N06022 weldneck flang

Pagina 3 - Temperature limits

Micro Motion® ELITE® Flow and Density Meters 11Pressure ratings continued Sensor pressure/temperature ratings with ASME B16.5 F304/304L weldneck flang

Pagina 4 - Accuracy and repeatability

12 Micro Motion® ELITE® Flow and Density MetersPressure ratings continuedSensor pressure/temperature rating with ASME B16.5 F304/304L lap joint flange

Pagina 5 - Liquid flow performance

Micro Motion® ELITE® Flow and Density Meters 13Pressure limits continued Sensor pressure/temperature ratings with Tri-Clamp compatible 316L hygienic f

Pagina 6 - Gas flow performance

14 Micro Motion® ELITE® Flow and Density MetersPressure ratings continued Sensor pressure/temperature ratings with VCO 316/316L fittings Models CMF010

Pagina 7

Micro Motion® ELITE® Flow and Density Meters 15Pressure ratings continued Sensor pressure/temperature ratings with VCO UNS N06022 fittings Sensor pres

Pagina 8 - Pressure ratings

16 Micro Motion® ELITE® Flow and Density MetersPressure ratings continuedSensor pressure/temperature ratings with EN1092-1 and DIN 304/304L weldneck f

Pagina 9

Micro Motion® ELITE® Flow and Density Meters 17Pressure ratings continuedSensor pressure/temperature ratings with JIS 2220 F316/316L weldneck flanges

Pagina 10 - Pressure ratings continued

18 Micro Motion® ELITE® Flow and Density MetersPressure ratings continuedSensor pressure/temperature ratings with JIS 2220 316/316L wafer flanges Sens

Pagina 11

Micro Motion® ELITE® Flow and Density Meters 19Pressure ratings continuedSensor pressure/temperature ratings with JIS 2220 304/304L lap joint flanges

Pagina 12

2 Micro Motion® ELITE® Flow and Density MetersMicro Motion ELITE flow and density metersMicro Motion Coriolis meters meet a vast range of application

Pagina 13 - Pressure limits continued

20 Micro Motion® ELITE® Flow and Density MetersEnvironmental effects Process temperature effectProcess temperature effect is defined as:• For mass flo

Pagina 14

Micro Motion® ELITE® Flow and Density Meters 21Hazardous area classifications UL(1)(1) The following products are not available with UL approval: sens

Pagina 15

22 Micro Motion® ELITE® Flow and Density MetersHazardous area classifications continued ATEXAll models with Model 2400S transmitter;Models CMFS010 and

Pagina 16

Micro Motion® ELITE® Flow and Density Meters 23Hazardous area classifications continued Model CMF010, CMF025, or CMF050 with junction box connected to

Pagina 17

24 Micro Motion® ELITE® Flow and Density MetersHazardous area classifications continued Model CMF200 or CMF300 with junction box connected to MVD tran

Pagina 18

Micro Motion® ELITE® Flow and Density Meters 25Hazardous area classifications continued High-temperature models CMF200A, CMF200B, CMF300A, CMF300B, CM

Pagina 19

26 Micro Motion® ELITE® Flow and Density MetersHazardous area classifications continued Model CMF400 with core processorUse the above graph to determi

Pagina 20 - Environmental effects

Micro Motion® ELITE® Flow and Density Meters 27Hazardous area classifications continued Models CMFS010 or CMFS015 with core processorUse the above gra

Pagina 21

28 Micro Motion® ELITE® Flow and Density MetersHazardous area classifications continued Models CMFS010 and CMFS015 with Model 2200S transmitterUse the

Pagina 22

Micro Motion® ELITE® Flow and Density Meters 29Materials of construction Weight Wetted parts(1) (2)(3)(1) General corrosion guides do not account for

Pagina 23 - Max ambient temp (°C)

Micro Motion® ELITE® Flow and Density Meters 3Temperature limits All models except high-temperature models(1) (2) (3) (4)(1) Temperature limits may be

Pagina 24

30 Micro Motion® ELITE® Flow and Density MetersDimensionsModels CMFS010 and CMFS015 with Model 2200S, Model 2400S, or enhanced core processorModelNo.

Pagina 25

Micro Motion® ELITE® Flow and Density Meters 31Dimensions continuedModels CMFS010 and CMFS015 with Filling Mass Transmitter ModelNo. of flow tubesFlow

Pagina 26

32 Micro Motion® ELITE® Flow and Density MetersDimensions continuedModel CMF010 ModelNo. of flow tubesFlow tube IDinches (mm)CMF010 1 0.11 (2.9)Dimens

Pagina 27

Micro Motion® ELITE® Flow and Density Meters 33Dimensions continuedModels CMF025, CMF050, and CMF100 ModelNo. of flow tubesDimensions(1)(2) in inches

Pagina 28

34 Micro Motion® ELITE® Flow and Density MetersDimensions continued Models CMF200 and CMF300 ModelNo. offlow tubesDimensions(1)(2) in inches (mm)(1) F

Pagina 29 - Materials of construction

Micro Motion® ELITE® Flow and Density Meters 35Dimensions continued Model CMF400 ModelNo. offlow tubesFlow tube IDinches (mm)CMF400 2 2.9 (73)Dimensio

Pagina 30 - Dimensions

36 Micro Motion® ELITE® Flow and Density MetersDimensions continued Electronics detail for Models CMF010, CMF025, CMF050, CMF100, CMF200, CMF300, and

Pagina 31 - Dimensions continued

Micro Motion® ELITE® Flow and Density Meters 37Dimensions continuedElectronics detail for Models CMF010, CMF025, CMF050, CMF100, CMF200, CMF300, and C

Pagina 32

38 Micro Motion® ELITE® Flow and Density MetersDimensions continuedHigh-temperature Models CMF200A, CMF200B, CMF300A, and CMF300B ModelDimensions in i

Pagina 33

Micro Motion® ELITE® Flow and Density Meters 39Dimensions continued High-temperature Models CMF400A and CMF400B Dimensions ininches(mm)Ø1 5/16(33)Flex

Pagina 34

4 Micro Motion® ELITE® Flow and Density MetersAccuracy and repeatability Electronics optionModel 2400S, enh. core processorOther MVD transmitter, std.

Pagina 35

40 Micro Motion® ELITE® Flow and Density MetersDimensions continued Electronics mounted on high-temperature sensor flexible conduit Electronics interf

Pagina 36

Micro Motion® ELITE® Flow and Density Meters 41Fitting optionsDimensions are in inches (mm). Fittings listed here are standard options. Other types of

Pagina 37

42 Micro Motion® ELITE® Flow and Density MetersFitting options continuedModels CMFS010H and CMFS015H Models CMFS010P and CMFS015P Code Description Dim

Pagina 38

Micro Motion® ELITE® Flow and Density Meters 43Fitting options continuedModel CMF010M Model CMF010H Code Description Dim. A Dim. B172 DN25 PN40 EN 109

Pagina 39

44 Micro Motion® ELITE® Flow and Density MetersFitting options continuedModel CMF010L Model CMF010P Model CMF025M Code Description Dim. A Dim. B413 1/

Pagina 40

Micro Motion® ELITE® Flow and Density Meters 45Fitting options continuedModel CMF025M continued Model CMF025L Model CMF025H Code Description Dim. A Di

Pagina 41 - Fitting options

46 Micro Motion® ELITE® Flow and Density MetersFitting options continuedModel CMF050M Code Description Dim. A Dim. B009 1/2” CL150/300 bolt kitASME B1

Pagina 42 - Fitting options continued

Micro Motion® ELITE® Flow and Density Meters 47Fitting options continuedModel CMF050L Model CMF050H Model CMF100M Code Description Dim. A Dim. B413 1/

Pagina 43

48 Micro Motion® ELITE® Flow and Density MetersFitting options continuedModel CMF100M continued Model CMF100L Model CMF100H Code Description Dim. A Di

Pagina 44

Micro Motion® ELITE® Flow and Density Meters 49Fitting options continued Models CMF200M and CMF200ACode Description Dim. A Dim. B312 DN40 PN40 EN 1092

Pagina 45

Micro Motion® ELITE® Flow and Density Meters 5Liquid flow performance Mass Volume(1)(1) Specifications for volumetric flow rate are based on a process

Pagina 46

50 Micro Motion® ELITE® Flow and Density MetersFitting options continued Model CMF200L Models CMF200H and CMF200BCode Description Dim. A Dim. B441 1-1

Pagina 47

Micro Motion® ELITE® Flow and Density Meters 51Fitting options continued Models CMF300M and CMF300ACode Description Dim. A Dim. B326 DN80 PN40 EN 1092

Pagina 48

52 Micro Motion® ELITE® Flow and Density MetersFitting options continuedModel CMF300L Models CMF300H and CMF300BModels CMF400M and CMF400ACode Descrip

Pagina 49

Micro Motion® ELITE® Flow and Density Meters 53Fitting options continued Models CMF400M and CMF400A continued Models CMF400H and CMF400BModel CMF400P

Pagina 50

54 Micro Motion® ELITE® Flow and Density MetersOrdering information Model Product descriptionStandard modelsCMFS010M Micro Motion Coriolis ELITE senso

Pagina 51

Micro Motion® ELITE® Flow and Density Meters 55Ordering information continued Code Case optionsFor all models except CMFS010 and CMFS015N Standard pre

Pagina 52

56 Micro Motion® ELITE® Flow and Density MetersOrdering information continued Code Electronics interfaceFor Models CMFS010 and CMFS0150 Model 2400S tr

Pagina 53

Micro Motion® ELITE® Flow and Density Meters 57Ordering information continued Code ApprovalsFor electronics interface codes 2, 3, 4, and 5M Micro Moti

Pagina 54 - Ordering information

58 Micro Motion® ELITE® Flow and Density MetersOrdering information continued Code Language (continued)N Norwegian CE requirements document and Englis

Pagina 55

Micro Motion® ELITE® Flow and Density Meters 59

Pagina 56

6 Micro Motion® ELITE® Flow and Density MetersGas flow performance When selecting sensors for gas applications, measurement accuracy is a function of

Pagina 57

 !""#"

Pagina 58

Micro Motion® ELITE® Flow and Density Meters 7Gas flow performance continued Typical mass flow accuracy and pressure drop with CMF100 and transmitter

Pagina 59 - Flow and Density Meters 59

8 Micro Motion® ELITE® Flow and Density MetersDensity range (liquid only) Vibration limits Power consumption Pressure ratings Range Up to 5 g/cm3 Up

Pagina 60 - WWW.micromotion.com

Micro Motion® ELITE® Flow and Density Meters 9Pressure ratings continued Sensor pressure/temperature rating with ASME B16.5 F316L/F316L weld neck flan