Emerson 1098-EGR Guía de instalación Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
3
Types 1098-EGR and 1098H-EGR





!
Warning

 
1 Valve Body
2 Body Flange
3 Cap Screw or Stud Bolt
4 Gasket
5 Travel Indicator Fitting
6 O-ring Retainer
7 Travel Indicator Stem O-Ring
8 Travel Indicator Hex Nut
9 Spring
10 Travel Indicator Stem
11 Cage
12 Port Seal
13 Seat Ring
14 Piston Ring
15 Upper Seal
16 Valve Plug
17 Cage O-Ring
18 Travel Indicator Scale
19 Travel Indicator Protector
 
20 Plug O-Ring
21 Travel Indicator Fitting or
Indicator Plug O-Ring
22 Travel Indicator Flange Nut
23 E-Ring
24 Drive Screw
25 Flow Arrow
26 Body Rating Plate
(not shown)
27 Indicator Plug
28 Spring Seat
29 Hex Nut (not shown)
31 Pipe Plug
32 Travel Stop
33 NACE Tag (not shown)
34 Tag Wire (not shown)
35 Fitting
36 Back-up Ring
37 O-Ring
Figure 1. Type EGR Main Valve Assembly
21
27
24
25
indicator pLug assemBLY
compLete cast iron

regulator inlet pressure is greater than the safe working
pressure of the downstream equipment.
Regulator operation below the maximum pressure
limitations does not preclude the possibility of damage from
external sources or debris in the line. The regulator should
be inspected for damage after any overpressure condition.

The regulator is factory set at approximately the midpoint
of the spring range or the pressure requested, so an
initial adjustment may be required to give the desired
results. With proper installation completed and relief
valves properly adjusted, slowly open the upstream and
downstream shutoff valves.

To change the outlet pressure, remove the closing cap or
loosen the locknut and turn the adjusting screw clockwise
to increase outlet pressure or counterclockwise to
decrease outlet pressure. Monitor the outlet pressure with
a test gauge during the adjustment. Replace the closing
cap or tighten the locknut to maintain the desired setting.
35A3167
19
10
37
7
21
6
3
2
24
26
14
15
9
11
18
22
8
35
36
5
31
4
20
23
28
17
1
16
13
12
Vista de pagina 2
1 2 3 4 5 6 7 8